Installation guide
FlipTop Touchpanel Control Center  Crestron C2N-FT-TPS4/TPS4-U 
programmed project until another set is uploaded from the PC. The PC may be 
disconnected from the control system or panel except during reprogramming. 
When you start the VT Pro-e project for this product, select C2N-FT-TPS4 as the 
panel type. 
For additional software information, refer to the help file provided with the software. 
The latest version of VT Pro-e can be obtained from the Crestron website. 
Uploading and Upgrading 
NOTE: Crestron recommends using the latest programming software and that each 
device contains the latest firmware to take advantage of the most recently released 
features. Please check the Crestron website (http://www.crestron.com/updates) for 
the latest versions of software and firmware. New users are required to register to 
obtain access to this site. 
Assuming a PC is properly connected to the entire system, Crestron programming 
software allows the programmer to upload programs and projects to the system and 
touchpanel and firmware to the wall plates after their development. However, there 
are times when the files for the program and projects are compiled and not uploaded. 
Instead, compiled files may be distributed from programmers to installers, from 
Crestron to dealers, etc. Even firmware upgrades are available from the Crestron 
website as new features are developed after product releases. In those instances, one 
has the option to upload via the programming software or to upload and upgrade via 
the Crestron Toolbox. 
The following sections define how one would upload a SIMPL Windows program to 
the control system, or upgrade the firmware of the C2N-FT-TPS4/TPS4-U. 
However, before attempting to upload or upgrade, it is necessary to establish 
communications. 
Communication Settings 
NOTE: For laptops and other PCs without a built-in RS-232 port, Crestron 
recommends the use of a PCMCIA card over a USB adapter, particularly if using 
Viewport. 
Establishing communications is an essential step when setting up the control system. 
Once communications are established with the control system, you can upload 
programming, update firmware, and use all the diagnostic tools available in Crestron 
Toolbox. 
Communications can be established using a serial (RS-323) connection, or by using a 
TCP/IP connection. For additional connection details, refer to “Establishing 
Communications with the Control System” in the latest version of the 2-Series 
Control Systems Reference Guide, Doc. 6256. 
The procedure in this section provides details for RS-232 communication between 
the PC and the control system. If TCP/IP communication is preferred, consult the 
latest version of the Crestron e-Control Reference Guide (Doc. 6052) or the 
respective Operations Guide for the control system. These documents are available 
from the Crestron website. Refer to the following figure for a typical connection 
diagram when uploading files. 
22 • FlipTop Touchpanel Control Center: C2N-FT-TPS4/TPS4-U  Operations & Installation Guide - DOC. 6398 