Installation guide
Crestron C2N-DBN12 & C2N-DBF12 Decorator Wall Panels
Operations & Installation Guide - DOC. 6200 Decorator Wall Panels: C2N-DBN12 & C2N-DBF12 • 19
NOTE: All signals listed in the table are DIGITAL unless noted. A
digital signal can be high (logic level of 1) or low (logic level of 0), and
have rising edge (low to high) transitions, and falling edge (high to low)
transitions.
C2N-DBF12 Symbol Signal Descriptions
SIGNAL
NAME DESCRIPTION
Input fbck1 thru fbck12 Activates feedback LEDs 1-12
High/1 = LED On
Low/0 = LED Off
IndicatorIntensity
(analog)
Controls LED indicator intensity.*
Ramp Level = 0-100% (If no signal
is connected, default is 100%.)
Output press1 thru press12 High/1 when button is being
pressed. Low/0 when button is not
being pressed.
*Sets maximum LED value for all feedback indicators simultaneously. Note that a setting of
0 (zero) is not Off – it is the lowest possible indicator intensity.
The following table lists press1-12 symbol’s cue names and their
corresponding buttons for the out-of-box C2N-DBF12 and C2N-DBN12.
Symbol’s Cue Name to Corresponding Keypad Button
SYMBOL NAME C2N-DBF12 C2N-DBN12
press1 CD
CLEAR
press2 FM
ENTER
press3 CD-2
1
press4 DSS
2
press5 TAPE
3
press6 AUX
4
press7 ON/OFF
5
press8 MUTE
6
press9 ◄
7
press10 VOL ▲
8
press11 ►
9
press12 VOL ▼
0