Specifications
Crestron DGE-2 Digital Graphics Engine
To setup a proxy server, select Use Proxy Server.
1. Enter the IP address or name of the proxy server.
2. If desired, specify addresses that should not use the proxy server (i.e.,
intranet addresses).
Touch OK to enable the proxy server connection and return to the “Security Setup”
window. Then touch Close to return to the setup menu.
Cresnet
The Cresnet button opens the “Cresnet Setup” window, which allows enabling or
disabling Cresnet and permits changing the Cresnet ID.
“Cresnet Setup” Window
Select Enable for normal Cresnet communication mode and Disable when the touch
screen is connected to a control system via Ethernet. Communication mode is factory
set to Disable.
The Cresnet network identity number (Cresnet ID) is displayed in the “Cresnet
Setup” window. Cresnet ID is a two-digit hexadecimal number. The hexadecimal
number can range from 03 to FE and must correspond to the Net ID set in the SIMPL
Windows program of the Cresnet system. Matching IDs between touch screen and
SIMPL Windows program is required if data is to be successfully transferred. The
Net ID for the DGE-2 is factory set to 03. No two devices in the same system can
have the same Net ID.
Two buttons below the hexadecimal display, Down and Up, decrease and increase
the Cresnet ID by one, respectively.
Select OK to accept the changes and return to the setup menu.
Operations Guide – DOC. 6809E Digital Graphics Engine with DigitalMedia™ CAT Connectivity: DGE-2 • 23