Specifications

Crestron C2COM-3 2-Series RS-232/422/485 Expansion Card
2-Series RS-232/422/485
Expansion Card: C2COM-3
Introduction
Functions and Features
The 2-Series C2COM-3 RS-232/422/485 Expansion Card provides RS-232, RS-422,
or RS-485 serial communication for a Crestron 2-Series Control System (PRO2 or
AV2 with cage card). The C2COM-3 fits in either control system’s Y-bus (3) slots.
The Y-bus provides high-speed communications and supports current and enhanced
Crestron control system expansion cards. All C2COM-3 ports can communicate with
the Network Poll Accelerator.
NOTE: The Network Poll Accelerator allows a 2-Series control system to maintain a
fast response time (high-speed communication) between the control system and a
large number of Cresnet devices. For more information, refer to the latest revision of
the Network Poll Accelerator Operations Guide (Doc. 6087).
The C2COM-3 supports baud rates up to 115,200 bps, and supports a variety of
communication parameters with hardware and software handshaking. Valid
parameters are shown in the Functional Summary.
Functional Summary
Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and
115200.
Parity may be even, odd, none, or zero stick (parity bit always 0). When
specifying the parity use E, O, N, or Z, respectively.
Data bits may be 7 or 8.
Stop bits may be 1 or 2.
Both XON/XOFF software handshaking and RTS/CTS hardware
handshaking are supported. XON/XOFF handshaking may be supported by
specifying XON (for both transmit and receive), XONR (for receive only),
or XONT (for transmit only). XON/XOFF and RTS/CTS handshaking are
mutually exclusive in the C2COM-3. If both are enabled, RTS/CTS is used.
If CTS handshaking is enabled, the CTS line is monitored by the C2COM-
3. The CTS line can also be enabled as a digital input to the control system;
the RTS line can be enabled as a digital output.
Supports RS-422. Refer to Non-standard COM Pinout table on page 4.
Break sequence can be generated under program control.
Supports RS-485. Refer to COM Pinout to RS-485 Bus table on page 4.
When programming in SIMPL™ Windows
, specify RS-485 and use
RS-485 communication settings.
Operations & Installation Guide - Doc. 8176 2-Series RS-232/422/485 Expansion Card: C2COM-3 1