Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Operations Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2002 Crestron Electronics, Inc.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Contents Integrated Dual Bus Control System: AV2 & PRO2 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications ..........................................................................................................
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Integrated Dual Bus Control System: AV2 & PRO2 Introduction Features and Functions Crestron’s AV2 and PRO2 2-Series Integrated Control Processors are designed for medium to large home and commercial network systems. Like all Crestron control processors, the AV2 and PRO2 units house the control system software program and provide connectivity for communication and control of all devices on the network.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 As with all of Crestron’s 2-Series control processors, the 2-Series Control Engine is a solutions-driven control technology that is at the very heart of the AV2 and PRO2 Integrated Control Systems. With speed, power, and massive memory, the 2-Series control systems are ideal for enhanced applications like media help desks, videoconferencing, distance learning, and entertainment facilities.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Specifications Specifications for the AV2 and PRO2 are given in the following table. AV2/PRO2 2-Series Integrated Control System Specifications SPECIFICATION DETAILS ® CPU 32-Bit Motorola ColdFire Processor Processor Speed 257 MIPS (Dhrystone 2.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Physical Description The AV2/PRO2 integrated control systems are housed in black enclosures with labeling on the front and rear panels. The dimensions shown in the following illustration apply to both units. AV2/PRO2 Overall Dimensions 17.025 in (43.24 cm) 9.688 in (24.61 cm) 4 • Integrated Dual Bus Control System: AV2 & PRO2 3.469 in (8.81 cm) Operations Guide - DOC.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Front and Rear Panels The front panels of both units include a single RS-232 computer port, standard LEDs, and two reset buttons. The PRO2 front panel also includes a two-line, 40character per line reverse LCD screen with menu function and selection buttons, and an extended bank of LED indicators. With the exception of the front panel computer port, all connections to the units are made through their rear panels.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Rubber feet are supplied and can be attached to the base of the unit for stability and to prevent slippage in shelf placement and stacking configurations. The unit may also be rack mounted by attaching the supplied metal flanges (ears). Refer to “Rack Mounting” on page 15 for details. Ports The ports provided on the front and rear panels of the AV2/PRO2 integrated control systems are described below.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Non-Standard COM Pinout PIN DIRECTION 1* 2 3 4 5 6 7 8 9 To AV2 or PRO2 To AV2 or PRO2 From AV2 or PRO2 From AV2 or PRO2 To AV2 or PRO2 From AV2 or PRO2 To AV2 or PRO2 From AV2 or PRO2 DESCRIPTION (RXD-) RS-422 Receive Data (Idles low) (RXD) RS-232 Received Data (TXD) RS-232 Transmitted Data (TXD+) RS-422 Transmit Data (Idles high) RS-232 and RS-422 Signal Common (RXD+) RS-422 Receive Data (Idles high) (RTS) RS-232 Request to Send (CTS) R
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 COMPUTER These DB9F connectors (one on front panel and one on rear) are used when programming with a PC. Each port is modem compatible. The modem and/or PC program cable is not included. FRONT PANEL REAR PANEL NET 24 Y Z G 24VDC 50W NET This connector (typical Crestron network port labeled 24 Y Z G) is used for expansion to Cresnet devices. Depending on the expansion slot load, there is a 50 W maximum load rating.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System RXD (COM A - F) These LEDs illuminate during reception of data from serial devices attached to the respective COM ports. TXD (COM A - F) These LEDs illuminate during transmission of data to serial devices attached to the respective COM ports. RTS (COM A - F) These LEDs illuminate to reflect the state of the RTS pin on the respective COM port. An illuminated LED means that the RTS line is high.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 permit the user to navigate through the menus and also to control the brightness of the display backlight. Below the display are six menu function buttons. These buttons offer extended features of the PRO2. For details, refer to "Programming the LCD Screen (PRO2 only)" on page 34.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Default Info Menu MSG This button displays a list (error log) of the most recent errors. Error messages may be the result of hardware or software failure, hardware incompatibility with software definitions, or a programming error.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 TIME This menu can only be obtained by entering the correct access code. The default access code is 1234. Use the Viewport (Functions | Set Front Panel Password (CNX / 2-Series only)) to assign a unique access code. The default Date/Time Menu, shown after this paragraph, permits alterations to the current system date and time shown on the top line. Select either Date or Time to open the respective submenu.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System NOTE: Only COM-type devices and cards in the SIMPL Windows program that are active (not commented out) are monitored. On-Board Memory The AV2 and PRO2 each have 36MB of built-in memory (non-volatile and volatile). A total of 36MB is broken down as follows: 4MB flash (non-volatile), 32MB DRAM (volatile), and 256KB NVRAM (non-volatile memory). Flash memory contains the file system inside the 2-series control engine.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 NOTE: If you extract NVRAM values to a file (Viewport, File transfer | Save NVRAM to File), to simplify restoring them in the event of file corruption or to distribute to identical control systems, remember that NVRAM values are position sensitive in the program. When saving the NVRAM is crucial to your application, it is recommended to place all symbols and/or modules that use NVRAM at the beginning of your program. When NVRAM (.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Industry Compliance As of the date of manufacture, this unit has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling (N11785). NOTE: This device complies with part 15 of the FCC rules.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 2. Position a rack ear so that its mounting holes align with the holes vacated by the screws in step 1. 3. Secure the ear to the unit with three screws from step 1, as shown in the illustration after this step. Ear Attachment for Rack Mounting (PRO2 shown in illustration) FASTEN WITH THE SAME (3) COVER SCREWS RIGHT SIDE VIEW OF PRO2 WITH OPTIONAL RACK MOUNTING EARS INSTALLED 4.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Network Wiring NOTE: When making wire connections, refer to the latest revision of the Cresnet Network Interconnect Drawing (Doc. 5411). The document can be obtained from the Downloads | Product Manuals section of the Crestron website (www. crestron.com). CAUTION: Possible equipment damage if miswired.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Wire Gauge Values RESISTANCE (R) WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT5 8.7 Tripled CAT5 NOTE: All network wiring must consist of two twisted-pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pair is the Y conductor and the Z conductor. NOTE: When daisy chaining network units, always twist the ends of the incoming wire and outgoing wire that share a pin on the network connector.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Hookup Connections for the 2-Series Integrated Dual Bus Control System TO ANY RS-232, -422, OR -485 DEVICE TO IRP2 OR SERIAL DEVICES TO CONTROLLABLE DEVICES FROM DEVICE OUTPUTS - CONTACT CLOSURES - SOLID STATE CLOSURES TO SERIAL PORT ON PC (ANOTHER DB9 CONNECTOR ON FRONT PANEL) TO CONTROLLABLE DEVICES TO ANY CRESNET OR STS NETWORK DEVICE TO OUTLET (POWER CORD SUPPLIED) Establishing Communication with the AV2/PRO2 Before uploading a pro
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 “Port Settings” Window: Default PC Settings for RS-232 Communication with the AV2/PRO2. To verify communication, click Diagnostics | Establish Communications (Find Rack). This should display a window that gives the COM port and baud rate. TCP/IP Connection Before you can communicate with the AV2/PRO2 over TCP/IP, you must use the RS-232 connection just described to configure the unit’s TCP/IP settings.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Once the cable connections are made, open the Crestron Viewport and click Setup | Communication Settings on the menu to display the “Port Settings” window. Then click TCP/IP as the connection type. Enter the IP address of the AV2/PRO2. “Port Settings” Window To verify communication, click Diagnostics | Establish Communications (Find Rack). This should display a window that gives the IP address and port number.
2-Series Integrated Dual Bus Control System c. Crestron AV2 & PRO2 Set the baud rate of the AV2/PRO2 control system to 115200, as follows: - Press and release the HWR button on the unit’s front panel. - Press and hold the SWR button for approximately three to five seconds. The Viewport console should display the following message: Viewport Message d. Release the SWR button. If communication still cannot be established: - Remove power from the control system.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System 2. Alternatively, click the Transfer button on the SIMPL Windows toolbar, or open Viewport and click File Transfer | Send Program. 3. Click Browse, locate the SPZ file and click Open. This will display the program's header information and enable one or both of the What to Send check boxes. If the program does not contain any SIMPL+ modules only the SIMPL Program check box will be enabled.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 “Send Program” Window Another way to verify that the program has been transferred successfully is to select Report Program Information on the Viewport Functions menu. Program information is also displayed in the Viewport console whenever power is removed and re-applied to the AV2/PRO2. Uploading Web pages to the AV2/PRO2 The AV2/PRO2 provides a built-in Web server for e-Control applications. The AV2/PRO2 allots 2.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System To upload a project: 1. From VT Pro-e: Click the Project | Upload button or click File | Upload Project. on the toolbar, From Viewport: Click File Transfer | Send Touchpanel or press Alt+T. 2. Select the network ID of the touchpanel, as set in SIMPL Windows, from the drop-down list. 3. Browse to the HEX or VTZ file to be uploaded. If the file is a HEX file, click Open to begin the transfer.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 program to run. If CFAUTORUN is disabled, then the user must either press the SW-R button on the front panel or issue a program reset through the Viewport to switch programs.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System CFPROJDIRS - Display a list of project directories on compact flash. CFTRANSFER - Transfer a project to/from compact flash. MAKEDIR - Create a file directory on compact flash. REMOVEDIR - Remove a file directory on compact flash.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 The Crestron AppBuilder is fully integrated with Crestron's suite of software development tools, including SIMPL Windows, VT Pro-e, Crestron Database, User IR Database, and User Modules Directory. The Crestron AppBuilder accesses these tools behind the scenes, enabling you to easily create robust systems. Programming with SIMPL Windows SIMPL Windows is Crestron’s graphical, Windows-based development tool for programming control systems.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Each port has a built-in serial driver with communication settings that must be specified in Configuration Manager: double-click a COM port to open the “Device Settings” window, and then click the Serial Settings tab. These settings define the protocol that a controlled serial device expects, and include the baud rate, parity, and the number of data bits and stop bits.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 In Program Manager, drag the C2I-IO8 symbol from Program View to Detail View.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Example 1 (recommended): The signal is driven low or left undefined. When goes low, Versiport 1 is at +5V. When goes high, Versiport 1 is shorted to ground. Example 2 (not recommended): The signal is driven high. When goes low, Versiport 1 is floating. When goes high, Versiport 1 is shorted to ground.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Example 6: A voltage source is placed on Versiport 1 and is set to 10 via an Analog Initialize symbol. The value of will not be propagated until it changes by at least 10. If the current value is 500, then a new value will not be reported until it changes to 510 or 490. Slot 7: C2I-RY8 The C2I-RY8 provides eight isolated relays for controlling low voltage contact closure devices such as drapes, screens and lifts.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System onto the existing control system in System Views, and click Yes when prompted to confirm the replacement. If the program contains SIMPL+ or User modules, the conversion might generate error messages. This is because modules and programs often contain symbols with “ambiguous” signals. For example, the inputs of the Serial to Analog symbol can be defined as either analog or serial.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 “Module Header Information” Window After you convert each module in a program, you can convert the program as described previously: drag the AV2/PRO2 onto the existing control system in System Views and click Yes to confirm the replacement. For further information about compile-time errors and detailed explanations about working with modules, refer to the SIMPL Windows online help file.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Default Front Panel Page Creating a Page with Front Panel Editor NOTE: The creation of a front panel page is discussed in this section. For more details, consult the SIMPL Windows help file. Search for Front Panel Editor. Assume that a page, as shown after this paragraph, is required.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Return to the “Menu1 – Choose Device” and double click on the VCR object. The “Edit Panel Object” window appears. From the Page Jump field, select “Menu2 – VCR Control”, as shown after this paragraph, and click OK. Select the Simulate check box to make the Front Panel Editor simulate an actual PRO2 front panel. Click on the VCR function button to enable the simulated page jump.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System note, to assign the join number. In the Page Channel area of this window, a specific number can be assigned or with the appropriate button assign the next or highest available. Asserting the digital signal for a particular page join number (fb*** on the SIMPL Window symbol) results in a jump to that page.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Object Types The sample discussed in the previous sections utilizes only one of the object types available from the “Edit Panel Object” window, shown below. These object types are not new to Crestron programmers; the same types are available in VisionTools™ Pro-e.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System 2-Series Integrated Dual Bus Control System Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Unexpected response from control system. Network devices are not communicating to the control system. From the Viewport, poll the network (F4) to verify communication. PWR LED does not illuminate. Control system is not receiving power.
2-Series Integrated Dual Bus Control System 6. Crestron AV2 & PRO2 At the Viewport prompt, type erase and press Enter. The following text appears in Viewport. CS>erase ->25%->50%->75%->100% Done CS> 7. Press ALT and O (not zero) on the keyboard. The “Open” window appears. 8. Find and select the correct firmware file (.CUZ) and click Open. 9. Once “Completed Successfully” appears in Viewport, type quit at the Viewport prompt and press Enter.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System “Passthrough Mode” Window COM Analyzer NOTE: Only COM-type devices and cards in the SIMPL Windows program that are active (not commented out) are monitored. Depressing the COM menu function button from the front panel Main Menu (default front panel page) displays a listing of all devices and cards that can be monitored. The listing follows the same order as the system tree in Configuration Manager.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Select Format Type Screen Once the BIN, ASCII, or HEX menu function button is selected, the display provides the T/R Screen. The Data Menu in the CNX Series control system contained a RESET and REFRESH menu function button. These buttons are not necessary for the PRO2, because the data is always 'live'. A buffer constantly records and recycles the data.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Further Inquiries If after reviewing this Operations Guide for the AV2 & PRO2, you cannot locate specific information or have questions, please take advantage of Crestron's award winning customer service team in your area. Dial one of the following numbers. • In the US and Canada, call Crestron's corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. • In Europe, call Crestron International at +32-15-50-99-50.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Software License Agreement This License Agreement (“Agreement”) is a legal contract between you (either an individual or a single business entity) and Crestron Electronics, Inc. (“Crestron”) for software referenced in this guide, which includes computer software and, as applicable, associated media, printed materials, and “online” or electronic documentation (the “Software”).
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document and certify that use of any and all Software at the time of the request is in conformity with Your valid licenses from Crestron of its authorized agent.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System This page intentionally left blank. Operations Guide - DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 5957A 08.02 Specifications subject to change without notice.