2. Place the CHV-TSTATRF in the SETUP mode by doing the following:
a. Press and hold the FAN button.
b. While the FAN button is being held, press and hold the RAISE
and LOWER buttons simultaneously.
c. Hold all three buttons for five seconds, after which the unit will
enter SETUP mode.
3. Once in SETUP mode, the display will indicate the currently selected
“Setup Parameter/Function”. Press and release the MODE button quickly
(must be released within one second) to change to the next
Parameter/Function in the list. When “Ac” is displayed, the CHV-TSTAT is
ready to start an infiNET Acquire.
4. Press either RAISE or LOWER to execute the Acquire function.
5. When the CHV-TSTATRF has established communications with an
infiNET Gateway, the currently displayed mode element (flame, snowflake
or “OFF”) will blink two times in two seconds. This flashing will occur
every eight seconds.
NOTE: If the CHV-TSTATRF is unable to establish communications with an
infiNET Gateway, the currently displayed mode element (flame, snowflake or
“OFF” will blink four times in two seconds. This flashing will occur every eight
seconds.
6. Take the C2N-MNETGW out of the ACQUIRE mode once all devices have
been acquired. Refer to the latest revision of the C2N-MNETGW guide
(Doc. 6317).
7. To exit from SETUP mode, press the FAN button on the CHV-TSTATRF.
NOTE: While in SETUP Mode, a period of one minute with no button activity will
cause the CHV-TSTATRF to revert to standard operation.
NOTE: While the Acquire is in progress, the unit will display a flashing “--”. When
the Acquire is finished, the unit will display “00”.
To communicate with the control system program, an MNET ID value between 03
and 20 must be assigned to the dimmer. Refer to “Identity Code” on page 8.
Release Gateway Connection
In some cases, it might be desirable to release the CHV-TSTATRF from a gateway.
If a CHV-TSTATRF is to be released from a gateway, the gateway information must
be cleared from the CHV-TSTATRF’s memory.
To clear a CHV-TSTATRF’s gateway information:
1. Place the CHV-TSTATRF in the SETUP mode by doing the following:
a. Press and hold the FAN button.
b. While the FAN button is being held, press and hold the RAISE
and LOWER buttons simultaneously.
c. Hold all three buttons for five seconds, after which the unit will
enter SETUP mode.
Operations & Installation Guide – DOC. 6490 infiNET™ Thermostat: CHV-TSTATRF • 11