infiNET™ Thermostat Crestron CHV-TSTATRF
Hardware Hookup
Make the necessary connections as called out in the illustration that follows this
paragraph. Apply power after all connections have been made.
Hardware Connections for the CHV-TSTATRF
RH: Reference Heat - Used for calls to the heating system
RC: Reference Cool - Used for calls to the cooling system
G: Fan - Energized to RC during call for fan
Y: Compressor - Energized to RC when compressor is run
C: 24 VAC common terminal supplies remote power to thermostat
W: Heat - Energized to RH during a call for heat in heat/cool systems or
aux heat in heat pump systems
O: Changeover control - Energized to RC during cooling modes
B: Energized to RC during heating modes
Setup Procedure
Acquiring the CHV-TSTATRF on the infiNET Network
Before an infiNET device can be used on an infiNET network, it must first be
acquired by a C2N-MNETGW gateway that is connected to a Cresnet network.
NOTE: A dimmer can be acquired by only one gateway.
To acquire a CHV-TSTATRF by a C2N-MNETGW, perform the following:
1. Put the C2N-MNETGW in the ACQUIRE mode, from the unit itself or from
Toolbox, as described in the latest revision of the C2N-MNETGW guide
(Doc. 6317).
NOTE: In environments where multiple gateways are installed, only one
gateway should be in ACQUIRE mode at a time.
10 • infiNET™ Thermostat: CHV-TSTATRF Operations & Installation Guide – DOC. 6490