Crestron CSP-LSP Cresnet® Lightning Strike Protector Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Crestron CSP-LSP Lightning Strike Protector Contents Cresnet® Lighting Strike Protector: Crestron CSP-LSP 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Applications.................................................................................................................
Crestron CSP-LSP Lightning Strike Protector ® Cresnet Lighting Strike Protector: Crestron CSP-LSP Introduction The CSP-LSP is an accessory designed to protect a Crestron® control system from lightning surges and other electrical disturbances brought through the Cresnet control line. Four-stage lightning suppression provides superior protection against damage to the control system caused by lightning strikes to remote Cresnet devices and wiring, especially outdoor equipment and underground cabling.
Lightning Strike Protector Crestron CSP-LSP that span multiple buildings, a separate CSP-LSP can be installed in each building to protect all of the local devices within each building. The CSP-LSP is designed for mounting to a wall or similar flat surface. Two protected CONTROL SYSTEM ports are provided, paralleled for easy daisy chaining to a second CSP-LSP or other Cresnet equipment. Four paralleled DEVICE ports accommodate the connections from one or more remote Cresnet wire runs.
Crestron CSP-LSP Lightning Strike Protector Applications The following diagrams show the CSP-LSP in a series of different applications. CSP-LSP Application for Local Systems Operations & Installation Guide – DOC.
Lightning Strike Protector Crestron CSP-LSP CSP-LSP Application for Long Runs 4 • Lightning Strike Protector: CSP-LSP Operations & Installation Guide – DOC.
Crestron CSP-LSP Lightning Strike Protector CSP-LSP Application for Multiple Building Systems Operations & Installation Guide – DOC.
Lightning Strike Protector Crestron CSP-LSP Specifications Specifications for the CSP-LSP are listed in the following table.
Crestron CSP-LSP Lightning Strike Protector Physical Description This section provides information on the connections available on your CSP-LSP. CSP-LSP Physical View Operations & Installation Guide – DOC.
Lightning Strike Protector Crestron CSP-LSP CSP-LSP Overall Dimensions 1.83 in (4.65 cm) 5.64 in (14.32 cm) 1 3 2 1.75 in (4.45 cm) 3.40 in (8.64 cm) 5.23 in (13.29 cm) 2 Connectors, Controls & Indicators # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 1 DEVICE (4) 4-pin 3.5mm detachable terminal blocks; Cresnet ports, paralleled, for connection to Cresnet wiring and devices that are subject to lightning strikes.
Crestron CSP-LSP Lightning Strike Protector Connectors, Controls & Indicators (Continued) # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 2 GROUND 3 CONTROL SYSTEM (2) 10-32 studs, chassis ground lugs2; 3 ft flat braided grounding strap included; Ground bus bar included for daisy chaining to a second CSP-LSP unit. (2) 4-pin 5mm detachable terminal blocks; Protected Cresnet ports, paralleled, for connection to control system and other protected Cresnet devices. 1.
Lightning Strike Protector Crestron CSP-LSP Industry Compliance As of the date of manufacture, the CSP-LSP has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
Crestron CSP-LSP Lightning Strike Protector Setup Network Wiring When wiring the network use Crestron Certified Wire. For more details, refer to “Check Network Wiring” on page 17. Supplied Hardware The hardware supplied with the CSP-LSP is listed in the following table.
Lightning Strike Protector Ground Clamp Crestron CSP-LSP Necessary grounding hardware is provided with your CSP-LSP. Refer to the image below when installing the braided ground strap (4505505) and ground clamp (2019803) to a grounded cold water pipe. CSP-LSP Ground Clamp Orientation Daisy Chaining Daisy chain up to two CSP-LSP units together using the provided grounding bus bar (2019534). Secure the grounding bar between two of the provided kep nuts (2004889) onto the grounding stud.
Crestron CSP-LSP Lightning Strike Protector Hardware Hookup The CSP-LSP can be connected locally to protect a nearby control system and Cresnet devices. The CSP-LSP can also be connected to remote Cresnet devices or another CSP-LSP to provide protection to Cresnet devices that are connected with substantially longer wire runs. Make the necessary connections as called out in the illustrations below and on the next page.
Lightning Strike Protector Remote Connections Crestron CSP-LSP Remote connections refer to connections made from the locally connected CSP-LSP to Cresnet devices connected by wire runs exceeding 500 feet or wire runs situated outdoors, including wire runs underground. Cresnet devices at these distant locations are referred to as remote Cresnet devices. A CSP-LSP can be connected at a remote location to provide additional protection to a unit or a series of remote Cresnet devices.
Crestron CSP-LSP Lightning Strike Protector Operation The CSP-LSP can be connected either locally or remotely, while up to two CSP-LSP devices may be daisy chained together in either connection configuration. Local CSP-LSP Operation Locally, one of the CONTROL SYSTEM ports must be connected to the control system.
Lightning Strike Protector Crestron CSP-LSP Daisy Chaining Up to two CSP-LSP units can be daisy chained when a C2N-HBLOCK is not a practical option. Daisy chaining two CSP-LSP units provide up to four protected CONTROL SYSTEM ports. When CSP-LSP units are being daisy-chained together, connect both of the available grounding studs to a good earth ground using the grounding straps provided with each unit. 16 • Lightning Strike Protector: CSP-LSP Operations & Installation Guide – DOC.
Crestron CSP-LSP Lightning Strike Protector Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CSP-LSP Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Device appears to be charred and branch of connected Cresnet units are not functioning. Device has failed due to lightning strike or power surge. Replace CSP-LSP.
Lightning Strike Protector Crestron CSP-LSP Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www.crestron.com/offices) for a listing of Crestron worldwide offices.
Crestron CSP-LSP Lightning Strike Protector Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6643A (2019895) 02.08 Specifications subject to change without notice.