Crestron CHV-TSTATRF infiNET™ Thermostat Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2007 Crestron Electronics, Inc.
Crestron CHV-TSTATRF infiNET™ Thermostat Contents infiNET™ Thermostat: CHV-TSTATRF 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications .............................................................................................................. 3 Physical Description..........
Crestron CHV-TSTATRF infiNET™ Thermostat infiNET™ Thermostat: CHV-TSTATRF Introduction The CHV-TSTATRF is a wireless networked thermostat featuring infiNET™ wireless technology. The CHV-TSTATRF is designed to be installed easily in place of a conventional thermostat without requiring additional control wiring.
infiNET™ Thermostat Crestron CHV-TSTATRF Heat/Cool Thermostat The CHV-TSTATRF is designed for heating and cooling control of baseboard, forced air, heat pump and dual-fuel heat pump HVAC systems. The large backlit LCD display provides a clear view of current temperature, setpoint, system mode, fan mode, system status and setup functions. Climate-control features include separate heat and cool setpoints and adjustable anticipators to prevent overshooting the desired temperature.
Crestron CHV-TSTATRF infiNET™ Thermostat Specifications Specifications for the CHV-TSTATRF are listed in the following table. CHV-TSTATRF Specifications SPECIFICATION Wireless RF Transceiver DETAILS C2N-MNETGW gateway/transceiver required (sold separately) Two-way RF, 2.4 GHz ISM Channels 11-26 (2400 to 2483.6 MHz), IEEE 802.15.
infiNET™ Thermostat Crestron CHV-TSTATRF CHV-TSTATRF Specifications (Continued) SPECIFICATION Weight DETAILS 6.7 oz (189.9 g) Available Models CHV-TSTATRFA infiNET Thermostat, Almond CHV-TSTATRFB infiNET Thermostat, Black CHV-TSTATRFW infiNET Thermostat, White Available Accessories C2N-MNETGW infiNET Gateway/Transceiver C2N-MNETRPT infiNET Repeater 1. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following these footnotes. 2.
Crestron CHV-TSTATRF infiNET™ Thermostat CHV-TSTATRF Overall Dimensions (Front and Side Views) 1.03 in (2.60 cm) 5.53 in (14.05 cm) 1 MODE 2 FAN 3 4.50 in (11.43 cm) 4 5 CHV-TSTATRF Overall Dimensions (Rear View) 3.27 in (8.30 cm) Operations & Installation Guide – DOC.
infiNET™ Thermostat Crestron CHV-TSTATRF CHV-TSTATRF (Connection View, front with cover removed) 6 6 Connectors, Controls & Indicators # CONNECTORS, CONTROLS & INDICATORS DESCRIPTION 1 MODE BUTTON Cycles through available System Modes: OFF, HEAT, AUX HEAT ONLY (for heat pump or dual-fuel systems only) and COOL. 2 FAN BUTTON Toggles fan setting between FAN AUTO and FAN ON. Raises the setpoint. 3 (RAISE BUTTON) 4 Lowers the setpoint.
Crestron CHV-TSTATRF infiNET™ Thermostat Industry Compliance As of the date of manufacture the CHV-TSTATRF has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. FCC ID: EROCWD1013 Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. 2.
infiNET™ Thermostat Crestron CHV-TSTATRF Installation NOTE: Installers should have a strong working knowledge of HVAC systems. Mounting the CVH-TSTATRF to the Wall The location of the thermostat can affect its performance and efficiency. Install the thermostat away from direct sunlight, drafts, doorways, skylights and windows. Also make sure the thermostat is conveniently located for control access and setup and do not mount on an exterior wall. Thermostats should be mounted 60 inches (152.
Crestron CHV-TSTATRF infiNET™ Thermostat Installation view Operations & Installation Guide – DOC.
infiNET™ Thermostat Crestron CHV-TSTATRF Wiring the CHV-TSTATRF to the HVAC System Make the necessary connections as called out in the illustrations that follow. A flat head screwdriver (not supplied) is required to attach the control wires from the HVAC system. Apply power after all connections have been made. The illustrations on the following pages show examples for connection to various types of HVAC systems.
Crestron CHV-TSTATRF infiNET™ Thermostat CHV-TSTATRF in Heat Only Application Optional, for power (Refer to “Basic Thermostat Setup” on page 15) Heat Relay System C Transformer 120 VAC R CHV-TSTATRF in Heat Only with Fan Application Optional, for power (Refer to “Basic Thermostat Setup” on page 15) Heat Relay Fan Relay System C Transformer 120 VAC R RH-RC jumper required since supply power is returned through RH NOTE: To run fan during heat calls, be sure to enable the HF parameter by setting it
infiNET™ Thermostat Crestron CHV-TSTATRF CHV-TSTATRF in Cool Only Application (Refer to “Basic Thermostat Setup” on page 15) C Optional, for power Y Compressor Relay G Fan Relay C Transformer R R RH-RC jumper required since supply power is returned through RH CHV-TSTATRF in Heat-Cool Application with Separate Systems Optional, for power (Refer to “Basic Thermostat Setup” on page 15) C W Heat Relay R 12 • infiNET™ Thermostat: CHV-TSTATRF R Y Compressor Relay G Fan Relay R Cooling C
Crestron CHV-TSTATRF infiNET™ Thermostat CHV-TSTATRF in Heat-Cool Application with Integrated Control Unit Optional, for power C (Refer to “Basic Thermostat Setup” on page 15) W Heat Relay Y Cool Relay G Fan Relay C Transformer R R RH and RC jumpered since control unit has them on a single terminal CHV-TSTATRF in Heat Pump System Application with Integrated Controller Optional, for power (Refer to “Basic Thermostat Setup” on page 15) C RH and RC jumpered since control unit has them on a sin
infiNET™ Thermostat Crestron CHV-TSTATRF CHV-TSTATRF in Dual-Fuel Heat Pump Application Optional, for power C (Refer to “Basic Thermostat Setup” on page 15) O Changeover Valve Y Compressor Relay G Fan Relay C Transformer R R Fossil Heat System C Transformer R NOTE: The diagram above applies where furnace control is not integrated into the heat pump system. 14 • infiNET™ Thermostat: CHV-TSTATRF Operations & Installation Guide – DOC.
Crestron CHV-TSTATRF infiNET™ Thermostat Basic Setup Basic Thermostat Setup The following documents the most common CHV-TSTATRF setup requirements. For full details on all setup options, refer to “Advanced Setup” which starts on page 18. Install two AA batteries (supplied) in the battery compartment. NOTE: When first setting up the CHV-TSTATRF, batteries are required, even if you plan to power it from a constant 24 VAC supply.
infiNET™ Thermostat Crestron CHV-TSTATRF If you have wired the thermostat so that 24 Volts AC will always be present on the “C” terminal (refer to “Wiring the CHV-TSTATRF to the HVAC System” on page 10), you can set the unit to run from this power supply, thus eliminating the need for batteries (except during initial setup). The thermostat will run on battery power if 24 VAC is not present.
Crestron CHV-TSTATRF infiNET™ Thermostat NOTE: An infiNET device can be acquired by only one gateway. Put the C2N-MNETGW in the Acquire mode, from the unit itself by pressing ACQUIRE or from Toolbox, as described in the latest revision of the C2N-MNETGW guide (Doc. 6317), which is available for download from the Crestron website (http://www.crestron.com/manuals). The gateway ACQUIRE LED lights.
infiNET™ Thermostat Crestron CHV-TSTATRF Advanced Setup Setup Mode After the CHV-TSTATRF is installed, it is necessary to set it up for a particular heating/cooling system. Please note that some of the setup parameters listed below will not always be available. Refer to “Setup Mode Parameters/Functions”, which starts on page 19 for details. Place the CHV-TSTATRF in the Setup mode by doing the following: 1. Press and hold the FAN button. 2.
Crestron CHV-TSTATRF infiNET™ Thermostat it will display “—” when a function is selected. All other display elements will be hidden (refer to “LCD Display” on page 25). NOTE: While in Setup mode, a period of one minute with no button activity will cause the CHV-TSTATRF to revert to standard operation, unless a function (such as an infiNET acquire) is executing. Setup Mode Parameters/Functions The following table shows the available setup parameters/functions.
infiNET™ Thermostat Crestron CHV-TSTATRF Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES Cool Anticipator CA 1–6 3 Lower setting results in more frequent cycles and faster response (tighter regulation). Higher setting results in less frequent cycles and slower response (looser regulation). The default value should suffice in nearly all installations.
Crestron CHV-TSTATRF infiNET™ Thermostat Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES Power Source Po 24V always available (24) or steal power (SP) 24 Selects source of input power for thermostat. 24VAC assumes constant power is available between the C and RH connectors. The steal-power function allows recovery of some power from the HVAC system when constant power is not available. Steal power may not work with some zone controllers.
infiNET™ Thermostat Crestron CHV-TSTATRF Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES Check Battery Life bA Not started (--) Estimated remaining battery life (0 – 99) N/A Gives estimated remaining battery life in percent. Restore Factory Defaults Fd Not started (--) In progress (flashing --) Finished (00) Button not held long enough (Er) N/A Restores all setup parameters to their default settings.
Crestron CHV-TSTATRF infiNET™ Thermostat Operation System Mode The MODE button on the CHV-TSTATRF will cycle the unit through all available system modes in the following order: Off, Heat, Aux Heat Only (for heat pump and dual-fuel systems) and Cool. In Off mode, all HVAC systems are disabled. In Heat mode, the thermostat uses the heating system to maintain the setpoint temperature.
infiNET™ Thermostat Crestron CHV-TSTATRF Setpoint” which can be specified by the control system program. This is handled automatically by the “Crestron CHV-TSTATRF w/5-2 Scheduler” module provided with the Crestron Database. Refer to “Programming with SIMPL Windows” on page 28 for more details about how to add this module to your program. Hold Hold allows the user to adjust the setpoint and will maintain that setpoint until the unit is taken out of Hold.
Crestron CHV-TSTATRF infiNET™ Thermostat LCD Display CHV-TSTATRF LCD Display 1 2 F C HOLD H C F A 8 9 OFF AUTO 3 4 5 6 7 LCD Display Elements # LCD DISPLAY ELEMENT DESCRIPTION 1 Large seven-segment digits Indicates current ambient temperature1, 2. In Setup mode, indicates current setup parameter/function. Display range is limited to –9º to 99ºF (-9º to 43ºC). If the ambient temperature is above 99º, the display will indicate 99º.
infiNET™ Thermostat Crestron CHV-TSTATRF LCD Display Elements (Continued) # LCD DISPLAY ELEMENT 7 OFF indicator 8 HOLD indicator 9 H, C, F & A indicators DESCRIPTION Displayed when the system mode is Off. Displayed when the HOLD setting is active. H – Displayed whenever a Heat Call is being made. C – Displayed whenever a Cool Call is being made. F – Displayed whenever a Fan Call is being made. A – Displayed whenever an Aux Heat Call is being made. 1.
Crestron CHV-TSTATRF infiNET™ Thermostat Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com. First-time users will need to establish a user account.
infiNET™ Thermostat Crestron CHV-TSTATRF Programming with SIMPL Windows NOTE: While SIMPL Windows can be used to program the CHV-TSTATRF, it is recommended to use SystemBuilder or D3 Pro for configuring a system. SIMPL Windows is Crestron’s premier software for programming Crestron control systems. It is organized into two separate but equally important “Managers”.
Crestron CHV-TSTATRF infiNET™ Thermostat C2Net Device, Slot 9 • Additional CHV-TSTATRF devices are assigned different MNET ID numbers as they are added. • If necessary, double click a device to open the “Device Settings” window and change the MNET ID, as shown in the following figure. “CHV-TSTATRF Device Settings” Window • Program Manager The ID code specified in the SIMPL Windows program must match the MNET ID of each unit.
infiNET™ Thermostat Crestron CHV-TSTATRF Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
Crestron CHV-TSTATRF Firmware infiNET™ Thermostat Check the Crestron website to find the latest firmware. (New users may be required to register to obtain access to certain areas of the site, including the FTP site.) Upgrade CHV-TSTATRF firmware via Crestron Toolbox. • Establish communications with the CHV-TSTATRF and display the “System Info” window. • Select Functions | Firmware… to upgrade the CHV-TSTATRF firmware.
infiNET™ Thermostat Crestron CHV-TSTATRF Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CHV-TSTATRF Troubleshooting TROUBLE No display Device does not follow control system commands. Heating/Cooling system is not operating. POSSIBLE CAUSE(S) CORRECTIVE ACTION No power from system. Check for +24V on C connector.
Crestron CHV-TSTATRF infiNET™ Thermostat CHV-TSTATRF Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Cannot change setpoint setting. The upper or lower temperature limits were reached. Heat setpoint range is 38º to 89ºF (3º to 32ºC). Cool setpoint range is 59º to 99ºF (15º to 37ºC) or 38º to 99ºF (3º to 37ºC) if extended cool mode enabled. System cycles too quickly. Anticipator setting is too low.
infiNET™ Thermostat Crestron CHV-TSTATRF NOTE: To manually enter bootloader, press and hold the MODE button for 10 seconds during unit power up. Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website (http://www.crestron.com/manuals). This link will provide a list of product manuals arranged in alphabetical order by model number.
Crestron CHV-TSTATRF infiNET™ Thermostat Appendix: About Heat Pumps A heat pump extracts available heat from one area and transfers it to another. Even cold air contains some heat and heat pumps can extract heat from the outside air on a cold day and transfer it indoors to maintain a comfortable temperature. A heat pump also works in reverse during the summer, extracting heat from indoors and transferring it outdoors.
infiNET™ Thermostat Crestron CHV-TSTATRF Glossary Anticipators Used to anticipate the drop or rise in temperature and energize the appropriate system before reaching the set point. Anticipators affect how tightly the setpoint temperature is maintained. Balance Point At low outdoor temperatures, the refrigeration cycle of a heat pump will not be able to supply the heating requirements without the aid of a supplementary heat source.
Crestron CHV-TSTATRF infiNET™ Thermostat HVAC Heating, ventilation and air conditioning. Interstage Differential The proportional temperature error (0.5 to 3.0º) to trigger the second stage (2-stage only), such as the aux heat for a heat pump type system. Run Fan in Heat Calls (Run Fan in Ht Calls) A device setting that activates the fan output during heat (W) calls. (For heat pump or dual fuel system types, this setting activates the fan during calls for auxiliary heat.
infiNET™ Thermostat Crestron CHV-TSTATRF Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron CHV-TSTATRF infiNET™ Thermostat This page is intentionally left blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6490 (2015101) 02.07 Specifications subject to change without notice.