- Crestron Electronics Digital Audio Processor With Room Control Operations Guide C2N-DAP8RC
Crestron C2N-DAP8RC  Digital Audio Processor with Room Control 
Operations Guide – DOC. 8187A  Digital Audio Processor with Room Control: C2N-DAP8RC • 57   
“Port Settings” Window 
NOTE: The parameters shown in the illustration above are the port settings for a 
PRO2 control system. Consult the Operations Guide for the control system being 
used for exact parameter selection. 
4.  To verify communication, select Diagnostics | Establish 
Communications (Find Rack). This should display a window that 
gives the COM port and baud rate. If communication cannot be 
established, refer to the “Troubleshooting Communications” section in 
the respective Operations Guide for the control system. 
Uploading a SIMPL Windows Program 
A control system source file has 
the extension .smw. A compiled 
SIMPL Windows file has the 
extension .spz for a 2-Series 
control system. 
The SIMPL Windows file can be uploaded to the control system using SIMPL 
Windows or via the Crestron Viewport. 
Upload via SIMPL Windows 
1. Start SIMPL Windows. 
2. Select File | Open to view the “Open” window, navigate to the SIMPL 
Window file (.smw), and click Open. 
3. Select Project | Transfer Program. 
Upload via Crestron Viewport 
1.  Verify that the procedure for “Communication Settings” that begins on 
page 55 has been performed. 
2.  As shown after this step, select File Transfer | Send Program 
(alternatively, press Alt+P) from the Viewport menu. 