32 • Digital Audio Processor with Room Control: C2N-DAP8RC   Operations Guide - DOC. 8187A 
Set up for communications as follows: 
1. Initially, the Pass To check box is not selected indicating a direct 
connection from your PC to the C2N-DAP8RC. Select Pass To if your PC 
and the C2N-DAP8RC are connected through the control system via 
Cresnet. Make certain the Cresnet ID setting is correct (50 is the default for 
the C2N-DAP8RC). Refer to “Identity Code” on page 12 for more 
information on setting the Cresnet ID. 
2.  Click on the Connection Settings Viewport Settings button to display the 
“Port Settings” window. Select RS-232 as the connection type. Verify that 
an available COM port is selected, and that all communication parameters 
and necessary options from the “Port Settings” window are selected as 
shown in the illustration on the next page. Click the OK button to save the 
settings and close the window. 
3.  Synchronize communication between the PC and the device by clicking the 
Transfer Configuration Load From Device button. This transfers any 
current settings of the C2N-DAP8RC to the DAT program. 
NOTE: Before making any adjustments via the DAT program, immediately save the 
program (use File | Save As) to preserve the current device settings. This is 
especially important if you are working on a device that has already been configured 
and you subsequently need to restore those settings. 