Installation Instructions

20
FIGURE 4
Install Sliding Panels – 4-Wide Door (cont.)
3. Take one of the sliding panels, either active or
inactive, and move it to the interior of the building.
4. Working from the interior, stand the panel
upright so the rollers are down and the interlock is
to the exterior (FIGURE 4) and closest to the fixed
panel (FIGURE 6).
IMPORTANT: Ensure the active or
inactive sliding panel is positioned on the
correct side of the door frame. The shootbolts
on the inactive sliding panel must match up
with the shootbolt keepers at the head and sill
(FIGURE 5).
5. Side-to-side, arrange sliding panel (FIGURE 6)
so its interlock will be located between the side
jamb and the fixed panel interlock.
If the sliding panel interlock is
placed on the wrong side of
the fixed panel interlock, the interlocks will
interfere with each other. The interlocks could
be damaged when trying to open the sliding
panel and may prevent the panel from opening.
The sliding panel interlock MUST
be located
between the side jamb and the fixed panel
interlock.
INACTIVE SLIDING PANELACTIVE SLIDING PANEL
INTERLOCK
INTERLOCK
ASTRAGAL
INTERIOR
EXTERIOR
FIXED
PANEL
SLIDING
PANEL
INTERIOR
INTERLOCK
SIDE JAMB
EXTERIOR
OPEN DOORWAY
FIGURE 5 – Sill Shown
FIGURE 6
SILL
SHOOT
BOLT
KEEPER
ADJUSTMENT
SLOT
SILL
SHOOT
BOLT
KEEPER
Cover
Removed
from Panel
EXTERIOR