User`s manual

226
The (HIST) function is able to store up to 599 dives, after which
the counter is reset.
NOTE: it is possible to vary the data stored in the HIST,
function, using the proper interface software (accessory).
Related topics:
• 2.7.2. - Date and time adjustment
• 2.7.3. - Units of measure setting
• 3.1. - air dive (DIVE )
• 3.2. - Hyper-oxygenated Nitrox mixture dive.
• 4.5. - Data PC transfer: compatible PC interface.
4.3.2. -
gage
program dive historic memory.
Cressi-sub computer is also equipped with a historic
memory for GAGE, program dives (HIST). To start this function,
depress button A ( ) in sequence until the (HIST) icon
appears on the display of the GAGE program (picture 50). This
program supplies information related to:
1 total time of gage, program dives, given in hours;
2 maximum depth reached during the dives (given in m or ft);
3 dives’ total number, shown by the “DIVE” icon
4 gage program icon
The (HIST) function is able to store up to 599 dives, after which
the counter is reset.
NOTE: it is possible to vary the data stored in the HIST,
function, using the proper interface software (accessory).
Related topics:
• 2.7.2. - Date and time adjustment
• 2.7.3. - Units of measure setting.
• 3.6. - gage (or depth gauge/Timer) program
• 4.5. - Data PC transfer: compatible PC interface.
4.3.3. -
FAEE
program apnoea dive historic memory
Cressi-sub computer is also equipped with a historic
memory for FAEE, program apnoea dives (HIST). To start this
function, depress button A ( ) in sequence until the
(HIST) icon appears on the display of the FAEE program (picture
36). This program supplies information related to:
1 TOTAL number of apnoea dives performed during the day;
2 Maximum depth reached in apnoea dives during the day,
given in meters (m) or feet (ft);
3 Time of the longest apnoea dive performed during the day,
given in minutes and seconds by the icon “MAX DIVE T”
The memory of apnoea dives performed during the day will
be reset automatically at midnight. It is though possible to
reset the apnoea dive historic memory by keeping button C
( ) depressed for about 5-6 seconds: the display
will be flashing and replacing the HIST icon with “CLEA” (pictu-
re 38), until all data stored in the apnoea dive historic memory
have been fully cancelled (picture 39).
Since the frequency of computer’s data adjustment in
the FAEE program (every second), the reset function is especial-
ly important, in order not to fill up the available memory too soon.
NOTE: it is possible to carry out the above procedure only
for the HIST function of computer s FAEE program.
NOTE: the apnoea dive historic memory reset does not affect
in any way the data transferring through the PC interface.
EDY.qxd:EDY Manuale2006-2.qxd 20-06-2008 11:52 Pagina 226