User`s manual

218
Same information is given even when the computer is taken
out of water and the contact “E” switches off. In this case the
display will change as shown in picture 35-b, delivering fol-
lowing information:
1 Surface (or recovery) time, given in minutes (1 a) and
seconds (1 b);
2 Time of
last
apnoea dive, given in minutes and seconds
by the icon “DIVE T.”;
3 Maximum depth reached during
last
apnoea dive, given
in meters (m) or feet (ft) by the icon “MAX”.
By depressing button D ( ), you get to the view of
apnoea dives memory and history (HIST), which delivers fol-
lowing information (picture 36):
1 TOTAL number of apnoea dives performed during the day;
2 Maximum depth reached during the apnoea dives of the
day, given in meters or feet;
3 Time of the longest apnoea dive of the day, given in minu-
tes and seconds by the icon “MAX DIVE T”.
By depressing button D ( ) once more, you get back to
the main view (picture 37), which shows the current time; by
depressing button D ( ) once more, you get back to the
view of the surface values as shown in picture 35-b.
In case the computer is plunged again underwater, and the
contact “E” switches on, same values will remain on the
display, which will change as shown in picture 35-a.
After ten minutes of surface time elapsing since last apnoea
dive, the display will change as follows: if the computer is
underwater, the contact “E” is on, and the display will change
as shown in picture 31-b; if the computer is taken out of water,
the display will get back to the main view shown in picture 37.
Related topics:
• 2.7.3. - Units of measurement setting
• 3.7. - FAEE (or Apnoea) program
• 3.7.2. - Apnoea dives memory and history (HIST) reset
• 4.3.3. - FAEE dives memory and history
3.7.2. - Apnoea dives memory and history (
HIST
) reset
Apnoea dives memory and history of the day will be reset
automatically at midnight. Though, it is possible to reset the
apnoea dives memory and history, by getting to mode and
depressing button A ( ) repeatedly, until the related
view will appear (picture 36). Now, keep button C
( ) depressed during 5-6 seconds: the display will
be flashing and replacing the icon with “CLEA” (picture 38),
until the data stored in the apnoea dives memory will be enti-
rely cancelled (picture 39).
Since the high frequency of data updating in computer’ s
FAEE mode (every second), the resetting function is particularly
important, in order not to fill the available memory too soon.
NOTE: it is possible to carry out the above procedure only
for the
HIST
function of computer’ s
faee
mode.
NOTE: the apnoea dives memory reset does not affect at
all the data to be downloaded through the PC interface.
Related topics:
• 3.7.1. - Surface interval after an apnoea dive (SURF) /
Apnoea dives memory and history HIST
• 4.3.3. - FAEE dive memory and history
• 4.5. - Data PC transfer: compatible PC interface
EDY.qxd:EDY Manuale2006-2.qxd 20-06-2008 11:52 Pagina 218