User`s manual
209
3.2. - HYPER-OXYGENATED MIXTURES DIVE
(
DIVE
program)
3.2.1. - Before a Nitrox dive
DANGER: the use of this computer with Nitrox is
exclusively
intended for divers who have attended a full
training course on the use of such mixtures.
DIVE Nitrox program of Cressi-sub computer allows
making saturation and de-saturation computations for a dive
carried out using a hyper-oxygenated mixture (Nitrox or
EANx) and starts any time the preset DIVE program’s para-
meters are varied, or any time the mixture’s FO2 is varied
(preset on FO%=21%). In this case, the (Nitrox) icon will be
displayed (picture 13) during the dive and as long as
remains set on Nitrox parameters.
Once Nitrox program is on, it is necessary to set on the
exact values of oxygen percentage (FO2) contained in the
cylinders to be used during the dive, after having analyzed
their content, so that the computer adapt its computing algo-
rithm to the new set values.
WARNING: computer is always set on DIVE pro-
gram for air dives, until the diver sets it on Nitrox program
(chapter 2.4.1. - dive parameters setting).
DANGER: do not dive with Nitrox cylinders without
checking their oxygen percentage.
WARNING: before diving, always check the oxygen per-
centage of the mixture set on the computer. This is done on
surface by depressing button A ( ) in sequence until
the DIVE display appears, showing your dive’s parameters.
WARNING: under the same dive conditions, a Nitrox mix-
ture requires longer no decompression times than air.
Although, it is strongly recommended to comply with the
maximum depth allowed by the selected Nitrox mixture.
Related topics:
• 2.4.1. - DIVE program parameters setting
• 2.7.3. - Units of measure setting.
• 3.3. - Nitrox parameters setting
• 3.3.3. - CNS toxicity display
• 3.3.4. - PO2 alarms
3.3. - Nitrox parameters setting.
3.3.1. - Partial pressure setting (PO2).
is preset on a basic PO2 value of 1.4 bar, in order to
guarantee the uppermost safety during any kind of dive.
Though, it is possible to vary the PO2 setting on values
between 1.0 bar and 1.6 bar. You just need to depress button
A ( ) to get to the (DIVE) display, as shown in picture 5,
then depress button C ( ) to select the parame-
ters you wish to vary according following order:
PO2 -> FO2 -> Safety Factor -> Max Depth -> OFF/ON
where PO2 is the oxygen partial pressure to be set by the
diver on values between 1.0 bar and 1.6 bar, by variations of
0.1 bar. The value is varied by depressing button D ( ).
Depress button A ( ) for some seconds to revert back
to the normal display (picture. 1).
ENGLISH
EDY.qxd:EDY Manuale2006-2.qxd 20-06-2008 11:51 Pagina 209