User's Manual

Copyright Crescend Technologies 8 Rev O
5. MAINTENANCE
5.1. INTRODUCTION
This section contains periodic maintenance and performance test information for the amplifier.
NOTE:
Check your sales order and equipment warranty before attempting to service or
repair the unit. Do not break the seals on equipment under warranty or the warranty
will be null and void. Do not return equipment for warranty or repair service until
proper shipping instructions are received from the factory.
5.2. PERIODIC MAINTENANCE
Periodic maintenance requirements are listed in Table 5-1. Table 5-1 also lists the intervals at
which the tasks should be performed.
WARNING:
Wear proper eye protection to avoid eye injury when using compressed air.
Table 5-1. Periodic Maintenance
TASK INTERVAL ACTION
Clean Air Vents/Check
Fan
30 Days Inspect and clean per paragraph 5-3.
Verify fan is working properly.
Inspect Cables and
Connectors and General
Site Conditions
6 Months Inspect signal and power cables for
frayed insulation and proper attachment.
Check RF connectors to make sure that
they are tight. Inspect the lightning
protection system and ground at the site.
5.3. CLEANING AIR INLETS/OUTLETS
The air inlets and outlets should be checked every 30 days and cleaned if necessary. If the
equipment is operated in a severe dust environment, it should be checked and cleaned more
often. If dust and dirt are allowed to accumulate, the cooling efficiency will be diminished. Using
either compressed air or a brush with soft bristles, loosen and remove accumulated dust and dirt
from the air inlet panels.
Check that the fan is running smoothly. A slow running or noisy fan may indicate an imminent fan
failure. Replace immediately with a similar to insure long term reliability. Heat is one of the
biggest factors in reducing the reliability of your amplifier. Make sure the fan has access to cool
and clean airflow within the rack.