TROUBLE-SHOOTING CHART:
FAILURE: POSSIBLE CAUSE:
1. Yellow light at switch does NOT light.
1a. Circuit breaker/fuse to wall outlet is blown
1b. Cord is unplugged from wall outlet.
1c. Switch is “OFF.”
2. Unit does not heat.
2a. Thermostat set too low or is “OFF.”
2b. Switch is “OFF.”
3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET
4. Blower does not work or makes noise. 4a. Defective blower
5. Excess moisture in cabinet. 5a. Open vent
5b. “Slack out” foods from oven or fryer for 5 minutes
before putting in hot cabinet.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT 208 VOLT 240 VOLT
Power Unit 1254-047 1254-048 1254-049
Blower Kit 0769-005-K 0769-006-K1 0769-006-K1
Heater Kit 0811-244 0811-245 0811-246
Thermostat Kit 0848-062-K 0848-062-K 0848-062-K
Thermometer Kit 5238-030-K 5238-030-K 5238-030-K
Power Cord 0810-029-02 0810-039-03 0810-039-03
Power Switch 0808-113-K 0808-113-01-K 0808-113-01-K