Datasheet

1212
Copyright © 2008-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
, the Cree logo and XLamp
®
are registered trade-
marks of Cree, Inc. UL
®
and the UR logo are registered trademarks of UL LLC.
12
xlAMP
®
xP-c lEDS
THERMAL DESIGN (CONTINUED)
Amber
Red, Red-Orange
0
50
100
150
200
250
300
350
400
0 20 40 60 80 100 120 140 160
Maximum Current (mA)
Ambient Temperature (ºC)
Rj-a = 20°C/W
Rj-a = 25°C/W
Rj-a = 30°C/W
Rj-a = 35°C/W
GRAPH 9
Amber
XPC
0
50
100
150
200
250
300
350
400
0 20 40 60 80 100 120 140 160
Maximum Current (mA)
Ambient Temperature (ºC)
Rj-a = 15°C/W
Rj-a = 20°C/W
Rj-a = 25°C/W
Rj-a = 30°C/W
0
50
100
150
200
250
300
350
400
0 50 100 150 200
Maximum Current (mA)
Ambient Temperature (ºC)
Rj-a = 20°C/W
Rj-a = 25°C/W
Rj-a = 30°C/W
Rj-a = 35°C/W