Programming instructions

3) Connecting the device
- The device must be supplied with 230-240V,50Hz.
- Mains connection must be ensured using a 3-wire
cable (Brown=
Live, Blue=Neutral, Black=Pilot wire),
through a connecting box. In damp premises, such as
bathrooms and kitchens,install the connecting box at
least 25cm from the ground.
-
A means for disconnection in all poles must be
provided in the fixed wiring in accordance with the
wiring rules.
- Do not connect to Earth.
Do not connect the pilot wire (black) to Earth.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified electrician
using special tools.
- If a device is
protected by a 30mA RCD (e.g. bathroom), the pilot wire supply must also be protected
by
this RCD .
Note: The screws supplied are of a standard type. .In case of particular fixing needs, use appropriate screws..
2
4
5
3
4) Fitting and removing the
brackets
WARNING
MAINTENANCE
IN CASE OF PROBLEM
- To maintain the performance of the device,about twice per year, clear the dust.
Do not use abrasive products.
-F
or models with a fan, use a vacuum cleaner to clear the air inlet and outlet grids, as well as the filter
(refer to the Filter paragraph).
- Every five years,have the machine’s interior checked and cleaned by a professional.
Model Outline Only
-
Y ou are recommended to have the appliance and the amount of fluid checked by a professional technician
after 6 years of use and replace it if necessary. The amounts of fluid to be introduced into the
appliances are: for 500W models 3.8 litres and for 750W models 5,9 litres.
- Any deteriorated fluid must be disposed of at a waste oil collection station.
- Prevent children from climbing on the device.Do not insert objects or paper in the device.
-Any
work on the electrical parts must be performed by skilled staff.
-
During first warming, a slight smell may be evident , due to the evacuation of compounds used
during the device’s manufacturing.
- The casing may be hot,even when the device is off.
Problem Check
The device
does not heat
- Check that the premises circuit breakers are ON or that the shedder (if you have
one) has not interrupted the device’s power supply.
- Check the air temperature in the room.
- Switch the device off,then back on (
s
switch):
) If the
t
indicator blinks 3 times:the measurement probe is damaged.Call your elec-
trician to ensure its replacement.
) If the
t
indicator blinks 5 times:power surge in device supply.Power off the device
(fuse, circuit breaker…),and call your electrician.
The heating
device
heats constantly
Check that the device is not located in a draught or that the temperature setting has not
been altered.
4
5 6
OUTLINE
SKYLINE
The appliance does not follow
the programming instructions.
Ensure that you use the programming unit correctly (refer to the instruc-
tions manual), that the programmer is correctly
fitted in its housing and
that it is operating normally (check the condition of the batteries).
The fan stops
prematurely
- Check that the air inlet grilles are not blocked.Proceed to clean them if necessary.
- Check that the room temperature has not reached too high a level.In this case,fan
stoppage is normal. Just wait for the ambient temperature to drop before reusing
the
Turbo mode.
- If you live at an altitude of more than 1000m,because the air is less dense this may cause
the item to rise in temperature more quickly.This may therefore become a repetitive
problem (without having any major effect on the service life of the machine’s compo-
nents).In all cases,follow the procedure below to restart the machine:
) Switch off the
appliance (switch s). )Wait at least 10 minutes
) Restart the
appliance (switch s).
Model with programmer only
Model with a fan only
Skyline Only
2) Carefully mark the drilling points with a pencil (draw a cross,4cm wide).
3) Drill the four holes.
4) Position the four hooks and screw them tight.
5)Attach the appliance and
6) lock it in place with the grub screw.
Panel heater cable
Live=brown
Neutral=blue
LIVE
NEUTRAL
Electricity
grid
Two possible cases
Pilot wire=Black
1st case: only one heater
2nd case: multiple heaters
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
2
220-240V insulated cable