Operating instructions
49
www.credaheating.co.uk
JOB NUMBER TITLE PG VERSION DATE Size at 100%
20157243 Creda Main Brochure
49
4 18/07/2013 A4 4pp + 52pp @ 100%
DESIGNER Org A/W A/W AMENDS
C:
DATE:
MW MW, MW, UL
www.credaheating.co.uk
JOB NUMBER TITLE PG VERSION DATE Size at 100%
20157243 Creda Main Brochure
48
4 18/07/2013 A4 4pp + 52pp @ 100%
DESIGNER Org A/W A/W AMENDS
C:
DATE:
MW MW, MW, UL
49
Floor
area Cavity walls Insulated cavity walls
m
2
Number of outside walls Number of outside walls
1 2 3 1 2 3
12m
2
ER500 ER500 ER400
+400n
ER400 ER400 ER500
16m
2
ER500 ER400
+400n
ER400
+500n
ER400 ER500 ER400
+300n
20m
2
ER400
+400n
ER400
+400n
ER500
+500n
ER500 ER400
+300n
ER400
+400n
24m
2
ER400
+400n
ER400
+500n
ER400
+400n
+400n
ER400
+300n
ER400
+400n
ER400
+400n
28m
2
ER400
+500n
ER500
+500n
ER400
+400n
+500n
ER400
+300n
ER400
+400n
ER500
+400n
32m
2
ER500
+500n
ER400
+400n
+400n
ER400
+500n
+500n
ER400
+400n
ER400
+400n
ER500
+500n
ForsizingofEco-Responseradiatorstoreplace
existingstorageheatersystems,replacethe
existingheaterwithasimilarlysized
Eco-Responseradiator,asindicatedbelow.
Due to the consistency of heat output from
Eco-Responseradiators,thiswillprovide
a significant improvement in room comfort
levels throughout the course of the day.
Existing heater Eco-Response
TSR12AW/MW ER300
TSR18AW/MW ER400
TSR24AW/MW ER500
When considering the correct replacement
foracombinationstorageheater,thefrequency
with which the convector component is
used should be taken into consideration
(i.e. if it is used often, the heater may
already be undersized). Therefore it is
recommended that combination storage
heaters are replaced with a larger size
ofEco-Responseradiator,toensurethere
is sufficient capacity within the system
to match the capability of the convector
heater being replaced. In the case
of a 24kW combination storage heater,
it is recommended that an additional
appliance–eitherasecondEco-Response
radiatororCredaNOBOpanelheaterisadded:
Existing heater Eco-Response radiator
TSR12ACW ER400
TSR18ACW ER500
TSR24ACW
2xER400,
orER500+panelheater
orER500+ameeffectre
Eco-Response radiator sizing – replacement systems
Eco-Response radiator sizing – first time installations
The following chart provides guidance on
radiator sizing for first time installations
inkeylivingareasforexistingbuildings.
Simply select the floor area of your room
from the left hand column, and choose the
correct number of outside walls from either
the cavity or insulated cavity wall columns.
These tables do not take into account
particularly old properties or those built
very recently. If your property fits into one
of these classifications, please complete
the form on page 50 so that we can provide
a more accurate assessment.
Note: A ceiling height of 2.4m and a minimum of 75mm of roof insulation is assumed.
Heater sizing table
Heater sizing table
How to use this
selection guide
The tables on this page are for use
withEco-Responseradiatorsonly–
for other products please refer to our
selectionchartsonpage48.Unlike
the charts on page 48, these tables
cover all applications – living room,
dining room, kitchen and hallway –
and are designed to provide for an
internaltemperatureof21°C.
Eco-Responseradiatorsaredesigned
to provide primary heating in main
living areas, including living rooms,
dining rooms, kitchen/diners and
hallways/landings. This should be
supplemented in other rooms,
such as bedrooms and bathrooms,
with Creda electronic panel heaters.