The tables below provide heater sizing guidance
for traditional electric heating systems, including
Quantum, storage heaters and panel heaters.
For traditional electric heating the preferred
options for living and dining rooms are Quantum
orTSRACWcombinationstorageheaters.
Knowingtheoorarea,thewallconstruction
and the number of outside walls, the heater
loading in kilowatts is indicated in the
appropriate table. These tables do not
take into account particularly old properties
or those built very recently. If your property
fits into one of these classifications, please
complete the form on page 50 so that we
can provide a more accurate assessment.
ForsizingguidanceforEco-Response
radiators please refer to page 49.
Living or dining room: Quantum or panel heaters.
HeaterloadinginkW.Temperature21°C
Floor
area
Solid walls
no. of outside walls
Cavity walls
no. of outside walls
Insulated cavity walls
no. of outside walls
m
2
1 2 3 1 2 3 1 2 3
12 1.84 2.16 2.88 1.60 1.92 2.48 1.12 1.28 1.68
16 2.08 2.48 3.20 1.84 2.32 2.88 1.36 1.60 1.92
20 2.64 3.12 3.92 2.32 2.72 3.44 1.68 1.92 2.32
24 2.96 3.44 4.32 2.64 3.12 3.76 2.08 2.32 2.64
28 3.28 3.92 4.80 2.96 3.44 4.24 2.16 2.48 2.96
32 3.52 4.32 5.28 3.28 3.76 4.72 2.40 2.72 3.20
ForTSRAWandMWheatersmultiplyloadingby2,forTSRACWmultiplyby1.25.
Commercial heating For greater control and economy of operation Quantum heaters
are recommended. Sizing is based on a single storey with a ceiling height of 3m and
a minimum of 75mm of roof insulation.
Office: Quantum or panel heaters.
HeaterloadinginkW.Temperature21°C
Floor
area
Solid walls
No. of outside walls
Cavity walls
No. of outside walls
Insulated cavity walls
No. of outside walls
m
2
1 2 3 1 2 3 1 2 3
15 2.16 2.96 4.08 2.00 2.56 3.52 1.68 2.08 2.64
20 2.64 3.52 4.48 2.40 3.12 4.00 2.08 2.56 3.12
25 2.96 4.08 5.20 2.72 3.68 4.56 2.40 3.04 3.60
30 3.52 4.72 5.84 3.36 4.24 5.20 2.88 3.52 4.16
40 4.80 5.92 7.68 4.40 5.36 6.72 3.92 4.48 5.36
50 5.28 6.80 8.40 4.96 6.24 7.44 4.48 5.28 6.08
ForTSRAWandMWheatersmultiplyloadingby2,forTSRACWmultiplyby1.25.
Kitchen: Quantum or panel heaters.
HeaterloadinginkW.Temperature18°C
Floor
area
Solid walls
no. of outside walls
Cavity walls
no. of outside walls
Insulated cavity walls
no. of outside walls
m
2
1 2 3 1 2 3 1 2 3
10 1.28 1.68 2.32 1.12 1.60 1.92
For all kitchens with
cavity wall insulation
direct heating is preferred.
12 1.52 2.16 2.64 1.36 1.84 2.32
14 1.68 2.40 2.88 1.60 2.08 2.48
16 1.92 2.64 3.12 1.68 2.32 2.72
ForTSRAWandMWheatersmultiplyloadingby2,forTSRACWmultiplyby1.25.
Bedrooms: For bedrooms panel heaters are recommended.
HeaterloadinginkW.Temperature18°C
Floor
area
Solid walls
no. of outside walls
Cavity walls
no. of outside walls
Insulated cavity walls
no. of outside walls
m
2
1 2 3 1 2 3 1 2 3
8 0.8 1.3 1.7 0.8 1.0 1.4 0.8 0.9 1.4
12 0.9 1.8 2.3 0.9 1.4 2.1 0.8 1.4 1.8
16 1.2 2.1 2.7 1.0 1.7 2.2 0.9 1.6 2.1
20 1.4 2.2 3.1 1.2 2.0 2.6 1.0 1.8 2.4
24 1.5 2.3 3.4 1.2 2.1 2.9 1.0 1.9 2.5
How to use this selection guide
ForTSRAWandMWheatersmultiplyloadingby1.5.
Heater sizing table
Heater sizing table
Creda provides a number of options,
to meet different property and
timescalerequirements.Ifyou
need to obtain an indication of
theheatingrequirementsfor
estimating or if you need heating
for one or two rooms, please use
the selection guide below.
Alternatively use our online
calculator at www.credaheating.co.uk
For single properties, please complete
the form on page 50 and send it
with a sketch plan to our heating
design department. We aim to provide
an accurate assessment within
7 working days.
For multiple properties, please send
us comprehensive scale drawings
(scale1:50or1:100)togetherwith
construction details and any other
relevant information. We offer a
14workingdayserviceforthis