Operating instructions
JOB NUMBER TITLE PG VERSION DATE Size at 100%
20157243 Creda Main Brochure
30
8 23/07/2013 A4 4pp + 52pp @ 100%
DESIGNER Org A/W A/W AMENDS
C:
DATE:
MW MW, MW, UL, UL,, UL
30
Key features
•Economicaluseofenergyutilisingthebestofstoredanddirectacting
heating technologies
•Contemporarydesign–looksgoodinanyhome
•Unobtrusive–takesupnomorespacethanatraditionalwetradiator
•Simpleone-touchelectroniccontrolswithchildlockfacility
•Rapidresponsetochangingtemperaturedemands
•Designedforrapidassemblytokeepinstallationcostsdown
•Requiresnoannualmaintenance
•Optionalcentralcontrollerfor4zonepilotwirelinkedheatingsystem
Technical Specification
•Elements(storage)–650Wincoloysheathed,
mineral filled elements
•Element(directacting)–cable-on-foilthinfaciapanel
•Thermostat(input)–integralelectronicchargelimiter.
Maximumcoretemperature670°C/690°Catfullcharge
•Thermostat(output)–integralelectronicthermostat
with child lock facility
•Thermalinsulation–Carbowool128kg/m
2
, Microtherm G
and calcium silicate
•Energyretentioncells–highdensitybondedmagnetite
•Protection(storage)–automaticresetcorelimitthermostat
and manual over-temperature cut-out
•Protection(directacting)–automaticresetlimitthermostat
and automatic reset over-temperature cut-out
•Finish–whitepolyesterandzinccoatedsteelwithgreybase
•Cable(storage)–1.6m2.5mm
2
3 core
•Cable(directacting)–1.6m0.75mm
2
2 core
•Supply–230/240VACsinglephase
Width
Height
Width
Feet width
Depth
Depth
Height
www.credaheating.co.uk
Warmth where it’s needed, when it’s needed in a single room
or across the home. A constant low level of background heat
prevents the fabric of the building from cooling. On demand,
this fast-acting appliance raises the temperature to meet your
needs, providing total control and low running costs.
Eco-Response
Storage radiant heaters
Mechanical panel heaters & electric storage heating – Eco-Response
Stored heat – maintains low level
background heat to keep the fabric of
the building warm, utilising economy
off-peak electricity.
Simple integral control on top of
the heater – allows easy adjustment
to achieve the user’s preferred
comfort temperature.
Radiantheat–rapidlyraises
temperaturetorequiredcomfort
level on demand.
Minimumclearancerequired
•75mmeithersideofheater
•150mminfrontoftheheater
•250mmdirectlyabovetheheater
Model Designed heat Charge Input rating, Input rating, Number Number Weight Height Width Depth Feet position
loss (kW) acceptance (kWh) off-peak (kW) radiant elt. (kW) of elements of bricks (kg) (mm) (mm) (mm) (mm)
ER300 0.7 9.1 1.3 0.28 2 8 65 712 600 130+10 295
ER400 1 13.65 1.95 0.34 3 12 94 712 830 130+10 523
ER500 1.4 18.2 2.6 0.39 4 16 124 712 1060 130+10 751
PWE4ZC 4 zone pilot wire central controller
Product Selector