Operating instructions

JOB NUMBER TITLE PG VERSION DATE Size at 100%
20157243 Creda Main Brochure
30
8 23/07/2013 A4 4pp + 52pp @ 100%
DESIGNER Org A/W A/W AMENDS
C:
DATE:
MW MW, MW, UL, UL,, UL
30
Key features
•Economicaluseofenergyutilisingthebestofstoredanddirectacting
heating technologies
•Contemporarydesign–looksgoodinanyhome
•Unobtrusive–takesupnomorespacethanatraditionalwetradiator
•Simpleone-touchelectroniccontrolswithchildlockfacility
•Rapidresponsetochangingtemperaturedemands
•Designedforrapidassemblytokeepinstallationcostsdown
•Requiresnoannualmaintenance
•Optionalcentralcontrollerfor4zonepilotwirelinkedheatingsystem
Technical Specification
•Elements(storage)–650Wincoloysheathed,
mineral filled elements
•Element(directacting)–cable-on-foilthinfaciapanel
•Thermostat(input)–integralelectronicchargelimiter.
Maximumcoretemperature670°C/690°Catfullcharge
•Thermostat(output)–integralelectronicthermostat
with child lock facility
•Thermalinsulation–Carbowool128kg/m
2
, Microtherm G
and calcium silicate
•Energyretentioncells–highdensitybondedmagnetite
•Protection(storage)–automaticresetcorelimitthermostat
and manual over-temperature cut-out
•Protection(directacting)–automaticresetlimitthermostat
and automatic reset over-temperature cut-out
•Finish–whitepolyesterandzinccoatedsteelwithgreybase
•Cable(storage)–1.6m2.5mm
2
3 core
•Cable(directacting)–1.6m0.75mm
2
2 core
•Supply–230/240VACsinglephase
Width
Height
Width
Feet width
Depth
Depth
Height
www.credaheating.co.uk
Warmth where it’s needed, when it’s needed in a single room
or across the home. A constant low level of background heat
prevents the fabric of the building from cooling. On demand,
this fast-acting appliance raises the temperature to meet your
needs, providing total control and low running costs.
Eco-Response
Storage radiant heaters
Mechanical panel heaters & electric storage heating – Eco-Response
Stored heat – maintains low level
background heat to keep the fabric of
the building warm, utilising economy
off-peak electricity.
Simple integral control on top of
the heater – allows easy adjustment
to achieve the user’s preferred
comfort temperature.
Radiantheat–rapidlyraises
temperaturetorequiredcomfort
level on demand.
Minimumclearancerequired
•75mmeithersideofheater
•150mminfrontoftheheater
•250mmdirectlyabovetheheater
Model Designed heat Charge Input rating, Input rating, Number Number Weight Height Width Depth Feet position
loss (kW) acceptance (kWh) off-peak (kW) radiant elt. (kW) of elements of bricks (kg) (mm) (mm) (mm) (mm)
ER300 0.7 9.1 1.3 0.28 2 8 65 712 600 130+10 295
ER400 1 13.65 1.95 0.34 3 12 94 712 830 130+10 523
ER500 1.4 18.2 2.6 0.39 4 16 124 712 1060 130+10 751
PWE4ZC 4 zone pilot wire central controller
Product Selector