5 - 6
5.5 Steps
5.5.1 Motion control step
Start the servo program Kn.
Kn
Designation range: K0 to K4095
(1) Description of operation
(a) The start accept flag for the axis designated in the designated servo program
Kn (n = 0 to 4095) is turned ON.
(b) The designated servo program Kn (n = 0 to 4095) is started.
v
t
Shift condition established
Start accept flag
(M200n)
(2) Error
In the following case, an error will occur and execution of the SFC program will
stop.
(a) When the designated servo program Kn does not exist.
(3) Precautions
(a) To change the current value within the SFC program, designate the CHGA
command using the servo program and call it at the motion control step.
(b) Even if the major or minor error occurs at or during the start of the servo
program, causing the servo program to be stopped due to error, the SFC
program will executed continuously. If the SFC program must be stopped
when an error occurs, input the error detection conditions at the transition
(shifting condition).
ABS-1
Axis 1 2000
Speed 10000
K10
<Description example>