A - 31
(2) Execution timing
Starting of the designated servo program is requested at the rising edge of the
SVST command (OFF ON).
(3) Operation error conditions
An operation error occurs in the following cases and the SVST command is not
executed.
(a) When the machine (set for reservation) is designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
(b) When the local machine is designated by object machine CPU head No.
input/output No. ÷ 16 [nl]
(c) When a CPU other than Q motion CPU is designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
(d) When the command is configured of devices other than usable device
(e) When 0 to 3DFH, 3E4H and following are designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
END END END END
SVST command
executio
Completion of command
acceptance at motion CPU side
ON
Servo program executio
ON
ON: For abnormal
completion only
Sequence program
1-scan
ON
SVST command
Command accept
flag
Start accept flag
(axis)
Motion SFC program
Command start accept
completion device (D1+0)
Device of status display
for command start