11.6 Writing to the motion CPU
Write the following data to the motion CPU:
Servo programs
Mechanism programs
Cam data
1) Stop the Q motion CPU.
2) Click on [Communication] and then the [Transfer]
menu in the MECHANISM EDIT window.
3) Click and select the 'Servo program', 'Mechanism
program' and then the 'Cam data' under "Transfer
data" in the COMMUNICATION dialog box.
After selecting the data to transfer, click on the Write
button.
(The servo setting data (system setting/servo setting
data) does not need to be written as the same
settings as the real mode set in chapter 6 are used)
4) A dialog box to confirm the connection destination
CPU and main unit OS will open, so click on the YES
button.
5) When the message "Completed normally." appears,
click on the OK button.
6) Click on the END button in the COMMUNICATION
dialog box to close the dialog box.
7) Reset the Q-PLC CPU to start the Q motion CPU.