Specifications

Table Of Contents
9 - 6
(Continued from previous page)
4) Set the "Automatic refresh setting" to 'Setting 2',
and set the following.
"Head device" : 'D6000'
"Number of #1 machine points" : '4'
"Number of #2 machine points" : '4'
5) Confirm that 'All machines stopped due to error in
#2 machine' under "Operation mode" is checked.
After checking, click the SYSTEM SETTING tab i
the BASIC SETTING dialog box.
6) Set the "Emergency stop input setting" to 'X(PX)',
and input '1F' for X(PX).
Check that "Operation cycle setting" is selected
under 'Automatic setting' and that "Turn M2000 ON
at switch (STOPRUN) is under operation at
STOPRUN.
After setting, click on the OK
button in the BASIC
SETTING dialog box.
7) The SYSTEM SETTING window will open.
The settings for each unit are explained in (2), (3)
and (4) on the following pages.