Specifications

Table Of Contents
6 - 17
6.1.13 Simultaneous start
Simultaneous start control using START
(1) Two to three types of servo programs (excluding START) are simultaneously
started.
(3) If three servo programs are for 1-axis to 4-axis control, up to 12 axes can be
simultaneously started.
(3) The servo program No. designated with the START command cannot be
indirectly designated with a word device (D, W).
INC-1
AXIS
SPEED
2, 50000.0
5000.00
INC-1
AXIS
SPEED
1, 100000.0
5000.00
m)
(mm/min)
START
K 64
K 65
200
100
0
0 100 200 300 (mm)50 150
50
REAL
<K 63>
Start point
End point
REAL
<K 64>
m)
(mm/min)
REAL
<K 65>