User manual

AT COMMANDS: DATA MODEM 2-17
AT\N3 Depending on the remote modem setting, the modem tries to make
a Normal, MNP or V.42 connection (Auto reliable). Hardware
Flow Check is authorised (factory setting).
AT\N4 The modem tries to make a V.42 (Reliable) connection
AT\N5 The modem tries to make an MNP (Reliable) connection.
Some types of modem will not accept an MNP connection. In such cases, use
the \N0 command (Buffering) or the \N1 command (Direct mode).
\S – Displaying the Configuration
If you enter AT\S0 the current modem configuration will be displayed, thus giving
you an overview of many different settings.
Table 4 Active Configurations Display (Example)
\W – Split Speed Operation
AT\W0 Not authorised (factory setting)
AT\W1 Authorised. V.23 operation is enforced, as with F3.
-K – Extended MNP Operation
This command determines whether the conversion of a V.42 connection to an
MNP connection is authorised.
AT-K0 Not authorised
AT-K1 Authorised (factory setting)
CMD DESCRIPTION / OPTION CMD DESCRIPTION / OPTION CMD DESCRIPTION / OPTION
--- -------------------- --- -------------------- --- --------------------
DTE BPS........19200 &C DCD OPTION.........1 )M CELLULAR.........OFF
DTE PARITY.....8NONE &D DTR OPTION.........2 S0 RINGS TO ANS.....000
DIAL MODE......PULSE &G GUARD TONE......1800 S1 RING COUNT.......000
LINE SPEED......NONE &K FLOW CONTROL.....RTS S2 <ESC> CHAR.......043
B BELL MODE........OFF &L NETWORK.........PSTN S3 <CR> CHAR........013
E CMD ECHO..........ON &P PULSE MODE.........0 S4 <LF> CHAR........010
F LINE MODE.......AUTO &Q ASYNC/SYNC.........5 S5 <BS> CHAR........008
L SPKR VOLUME......LOW &R RTS/CTS............1 S7 CONNECT TIME.....060
M SPKR CONTROL.......1 &S DSR OPT............1 S8 PAUSE TIME.......001
N AUTO MODE.........ON &T ENABLE RDL.......YES S12 ESC GUARD TIME...050
Q QUIET............OFF &X SYNC CLOCK.......INT S24 SLEEP INACT......010
V RESULT FORM.....LONG &Y PROFILE...........NO S30 CONNECT INACT....000
W EC MSG.............0 \A MAX BLK SIZE.....128 S32 XON CHAR.........017
X EXT RESULTS........4 \G REMOTE FLOW......OFF S33 XOFF CHAR........019
Y LONG SPACE DISC...NO \K BRK OPT............5 S36 FALLBACK ACTION..007
%C COMPRESSION.....BOTH \N ECL MODE........AUTO S37 MODE SELECT......000
%E AUTO RETRAIN.....OFF \W SPLIT SPEED......OFF S48 V42 NEG CTRL.....007
-K EXT. SERVICES......1 *H NEG. SPEED......HIGH S95 RES. CODE........002