2-10 AT COMMANDS: DATA MODEM
Z – Reset/Load a Stored Profile
The Zn command is used to carry out a Reset of an active configuration profile. In
this procedure, the NVRAM values are written into the relevant Registers and the
remaining parameters are changed again to the factory settings. You use the n pa-
rameter to select one of the configuration profiles which has been stored with &W
(n=0,1). Any command following the Z command in the same command line will
be ignored.
&C – M5 Control Line
The M5 signal at the serial interface to the DTE is always made with the &C0
command and the current status of the carrier signal from the remote modem is ig-
nored. With the &C1 command (factory setting), the M5 signal (DCD: Data Car-
rier Detect) displays the condition of the carrier signal which is received.
&F – Loading the Factory Settings
The &Fn command (n = 0,1) is used to read any of the factory settings stored in
the ROM. Any modified preliminary settings are over-written by this.
The &F1 setting is specially intended for initialisation in the BTX operating
mode, while &F0 is used for general data transmissions.
A Selection of &F0 Factory Settings
E1 Echo On
L0 Associated loudspeaker on low volume
M1 Loudspeaker On until connection is made
Q0 Modem messages switched on
V1 Complete alpha-numeric messages
Y0 Long Space Disconnect switched off
X4 Wait for dialling tone; engaged tone recognition
&B0 CCITT
&C1 M5 displays carrier recognition
&D2 Modem “hangs up” when S1 line (DTR) goes off
&G0 Guard tones switched off
&R1 M2 always On
&T4 Modem reacts to test loop request from remote party
S0=0 No automatic answer
\N3 Automatic operational mode dialling (buffering)
(Further settings are covered by the descriptions of the individual Commands and