Specifications

Portable Drying/Conveying Systems Chapter 3: Installation 20 of 76
3-3 Electrical Connections
When making electrical connections to your unit, ensure that you take into consideration and
make arrangements for the following:
A qualified electrician should make all electrical connections.
Fulfill all national, state, and local safety and electrical code requirements.
The serial tag lists voltage, phase, and amp draw information:
Line voltage must be within plus or minus ten percent (±10%) of the
voltage listed on the serial tag, or damage may occur. Phase imbalance
must be less than two percent (2%).
Connect main power to the dryer at the disconnect or terminals in the upper right
corner of the control enclosure.
Install a fused disconnect with a lockout feature in the power main leading to the dryer.
The power drop must include a ground wire.
Make sure all electrical connections are tight.
3-4 Setup Procedures
This section provides the procedures necessary for configuring your portable
drying/conveying system.
Configuration of your unit includes checking for proper blower rotation and installing the
optional aftercooler (on 60 cfm models). We recommend that you carry out these procedures
in the order given here.
Note: Before carrying out these procedures, install all equipment
as described in this section.
Checking for Proper Blower Rotation
Caution! In three-phase models, incorrect phasing of power leads can cause
backward rotation of blower motors and CONTAMINATION OF THE
DESICCANT!
Always check blower rotation before putting material in the drying hopper!
The blower is rotating properly when air flows from the delivery outlet.
Note: Holding your hand in front of the air return will also
indicate if the blower rotates in the proper direction (by
feeling suction).
If the three-phase blower rotates improperly, reverse any two wires at the fused disconnect
outside the dryer or at the disconnect/terminal in the control enclosure. This assures that the
blower rotates in the proper direction.
Drying Hopper Air Trap Considerations
Our exclusive air trap assembly on the top of the drying hopper prevents ambient air from
contaminating the material being dried. To ensure that your unit will operate at peak
efficiency, do the following: