Instruction manual

2-1
accQcomm Interface Module
Section 2 Installation and Operation
2.1 Programming The accQcomm’s configuration software is a simple program for
managing your site files. Install the program by inserting the
CD-ROM in the appropriate drive on your PC. Run the appli-
cation accQcomConfigSetupV1.00.exe.
2.1.1 Configuration
Software
Connect your PC to the accQcomm’s serial configuration port on
the front of the unit, or connect to the Ethernet port on the back,
and open the accQcomm configuration software.
Tabs The five tabs, Site, Communication, Alarms, and Output, and
Smoothing are used to set up the site and configure the transfer
of data.
Menu File Open an existing site file by selecting File > Open Configu-
ration. Save a new site file by selecting File > Save Configu-
ration. The file type will end in .cfg.
Program – Use Program > Send Configuration to open the
Connect window and save new program settings to the
accQcomm. To set the accQcomm time clock or zero the totalizer,
check the box(es) next to these options. Click Program to save the
new settings. The unit will be reinitiated with the new settings.
Use Program > Read Configuration to load the accQcomm’s
program settings into the current site file.
Software – Install updates to the accQcomm’s software by
selecting Software > Flash Software.
2.1.2 Connecting Without
Configuration
Software
Teledyne Isco recommends connecting to the accQcomm with the
configuration software provided. However, if you need to connect
to the accQcomm using a basic utility program, such as Hyper-
Terminal®, Table A-1 in Appendix A contains all accQcomm
commands and their definitions.
Connect your PC to the accQcomm’s serial configuration port on
the front of the unit (at 57,600 bps, 8 bits, no parity, 1 stop bit, no
flow control), or Ethernet port on the back, and use keystrokes
CTRL + D.
Once connection is established, the accQcomm will return the
header [ENTERED CONTROL MODE], followed by the prompt,
?>.
All settings are programmable with this method, but commands
must be entered into the computer and saved to the unit’s flash
memory. After saving the new program with the SS command,
restart the accQcomm with the SR command. The new program
will be applied upon restart.