User's Manual
28
Date of Origin – 02/01/08
Error Codes:
Additional Troubleshooting:
Problem Description Solution
Tarp will only run one direction Moisture between FWD & REV terminals, clean and add
dielectric
grease
Module clicks, motor will not run M1 & M2 shorted together or motor inter¬nally shorted, find
and
eliminate short
LED Activity Description Duration of LED Activity
Solid Unit functioning properly During Operation
2 blinks System Overload Shutdown 2 times
3 blinks Module Overload Shutdown Until next button press
4 blinks Motor Overheat Shutdown Until next button press
5 blinks High Voltage Shutdown (> 16V) Until next button press
6 blinks Low Voltage Shutdown (<7.5V) Until next button press
Loose connections before control box Check all connections from tractor to
back of control box
Bypass amperage control module in
junction box
Old amperage control module still
connected in junction box
7 blinks Mis-wired or No Load Until next button press
Mis-wired – Power leads crossed Switch the power leads (red stripe
should be positive)
Switch M2 and ground wire
power ground is connected to the
M2 post Check all connections for tightness
No Load – loose connection at the back
of box or at the motor Check with repair facility to replace
wire
broken wire, short in the system