communication applications, the "LAN" port of the device is usually not
connected to any device.
2.2 Restore to the Factory Settings
When the user forgets the IP of CFORCE N100, the webpage of CFORCE
N100 cannot be opened again. In this case, we choose manual operation, as
shown in the figure below, hold down the Reset button for 5-10 seconds, and wait
until all the LED lights are on, you can loose on, the device has been restored to
the default factory settings. At the same time, the network port of the host directly
connected to CFORCE N100 will display two consecutive connections and
disconnections.
Figure 2-2 Restore to the factory settings
The main parameters of the default factory settings of CFORCE N100 are as
follows:
Table 2-1 Main parameters at the factory settings
Items
Default Settings
IP address
192.168.1.36
User name
admin
Password
admin
3 Quick Configuration
This chapter describe how to configure the device quickly.