User Manual

22
Chapter 9: DMX Control
Due to the small dimensions of the Creamsource Micro, it does not have full size
XLR DMX connectors. Instead, the DMX signals are accessible by using a breakout
cable plugged into the Accessory socket, which brings the signals out to 5 pin XLR
connectors. Part number for the breakout cable is: CSU-DMX-Y
When a valid DMX signal is present, the manual controls for the unit are disabled.
These are restored one second after loss of DMX signal.
The DMX address can be set through the menu system, with each unit requiring
2 address slots in basic 8-bit mode. The first address will control intensity, and the
next adjacent address controls colour temperature.
Termination
As with all DMX installations, the last
unit in the chain should be terminated.
This can be done through the
menu system, by selecting MENU-
>Advanced->DMX Terminated.
ADVANCED
High Speed
DMX 16 bit
DMX Smooth •
DMX Effects •
DMX Terminated •
CS_micro_UG_6PRINT.indd 22 23/01/2018 2:35 PM