5.1. Extinguishing media
foam, carbon dioxide or dry agent
5.2. Special hazards arising from the substance or mixture
May form explosive vapour/air mixtures
Forms hazardous decomposition products
CO,CO2
5.3. Advice for firefighters
Keep container(s) exposed to fire cool, by spraying with water
In case of fire, do not breathe fumes
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Shut off all ignition sources
Ensure adequate ventilation
Wear suitable protective clothing including eye/face protection.
Ground/bond container and receiving equipment.
Use explosion-proof electrical/ventilating/lighting/.../equipment.
6.2. Environmental precautions
Do not allow to enter public sewers and watercourses
6.3. Methods and material for containment and cleaning up
Absorb spillage in suitable inert material
6.4. Reference to other sections
For further information see section 8
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Keep away from heat and sources of ignition
Take precautionary measures against static discharges
Equipment should be earthed
Use explosion-proof electrical/ventilating/lighting/.../equipment.
Use only non-sparking tools.
Do not breathe aerosols or vapours.
Ensure adequate ventilation
Avoid contact with skin and eyes.