Certifications 2

SECTION 12: Ecological information
12.1. Toxicity
Harmful to aquatic life with long lasting effects.
Components Test ResultsSpecies
Dipropylene glycol monomethyl ether (CAS 34590-94-8)
Aquatic
Acute
EC50Algae 969 mg/l, 96 hAlgae
EC50Crustacea 1919 mg/l, 48 hDaphnia
LC50Fish 10000 mg/l, 96 hFish
Chronic
NOECCrustacea 0.5 mg/l, 22 dDaphnia
Hydrocarbons, C13-15, n-alkanes, isoalkanes, cyclics, < 2% aromatics
Acute
IC50Other 1000 mg/l, 72 hPseudokirchnerella subcapitata
NOEL 1000 mg/l, 72 hPseudokirchnerella subcapitata
Aquatic
Acute
IC50Fish 1000 mg/l, 96 hOncorhynchus mykiss
Hydrocarbons, C6-C7, n-alkanes,isoalkanes,cyclics,< 5% n-hexane
Aquatic
Acute
EC50Algae 30 - 100 mg/l, 72 hAlgae
EC50Crustacea 3 mg/l, 48 hDaphnia
LC50Fish 11.4 mg/l, 96 hFish
No data is available on the degradability of any ingredients in the mixture.
12.2. Persistence and
degradability
No data available.
12.3. Bioaccumulative potential
Partition coefficient
n-octanol/water (log Kow)
Dipropylene glycol monomethyl ether 0.004
Bioconcentration factor (BCF)
Not available.
No data available.
12.4. Mobility in soil
This mixture does not contain substances assessed to be vPvB / PBT according to Regulation
(EC) No 1907/2006, Annex XIII.
12.5. Results of PBT and vPvB
assessment
None known
12.6. Endocrine disrupting
properties
12.7. Other adverse effects
The product contains volatile organic compounds which have a photochemical ozone creation
potential.
GWP: 2
SECTION 13: Disposal considerations
13.1. Waste treatment methods
Dispose of in accordance with local regulations. Empty containers or liners may retain some
product residues. This material and its container must be disposed of in a safe manner (see:
Disposal instructions).
Residual waste
Since emptied containers may retain product residue, follow label warnings even after container is
emptied. Empty containers should be taken to an approved waste handling site for recycling or
disposal. Do not re-use empty containers.
Contaminated packaging
EU waste code
The Waste code should be assigned in discussion between the user, the producer and the waste
disposal company.
Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Contents
under pressure. Do not puncture, incinerate or crush. Do not allow this material to drain into
sewers/water supplies. Do not contaminate ponds, waterways or ditches with chemical or used
container. Dispose of contents/container in accordance with local/regional/national/international
regulations.
Disposal methods/information
Dispose in accordance with all applicable regulations.
Special precautions
SDS UK
Material name: Rost Flash - Manufacturers
BDS000206AE Version #: 01 Issue date: 10-March-2021