Certifications 2

Safety Data Sheet
Regulation EC No 1907/2006 Art.31
Productname :
ECO Leak Finder
Creationdate :
02.06.20 Version : 6.0
Ref.Nr.:
BDS001564_3_20200602 (EN)
Replaces:
BDS001564_20200423
CRC Industries Europe bvba
Touwslagerstraat 1, 9240 Zele Belgium
Tel (+32) (0) 52 / 45 60 11 Fax (+32) (0) 52 / 45 00 34 www.crcind.com
7.1. Precautions for safe handling
Keep away from heat and sources of ignition
Do not spray on a naked flame or incandescent material.
Do not pierce or burn aerosols, even after use.
Do not breathe aerosols or vapours.
Ensure adequate ventilation
Avoid contact with skin and eyes.
Wash thoroughly after use
Wear protective gloves/protective clothing/eye protection/face protection.
7.2. Conditions for safe storage, including any incompatibilities
Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep out of reach of children.
7.3. Specific end use(s)
Gas leak detector
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Exposure limits :
Hazardous ingredient
CAS-nr.
method
National established exposure limits, United Kingdom
dinitrogen oxide
10024-97-2
TWA
100 ppm
National established exposure limits, Ireland
dinitrogen oxide
10024-97-2
TWA
50 ppm
STEL
-
8.2. Exposure controls
Control procedures :
Ensure adequate ventilation
Keep away from heat and sources of ignition
Personal protection :
Take precautions to avoid contact with skin and eyes when handling the
product.
It is good practice to wear gloves and to provide adequate ventilation whenever
using the product.
In all cases handle and use the product in accordance with good industrial
hygiene practices.
inhalation :
In case of insufficient ventilation, wear suitable respiratory equipment.
recommended respiratory protection:
Air purifying respirator equiped with organic gas/vapor cartridge (type A)
hands and skin :
When handling the product wear chemical-resistant gloves (standard EN 374).
Use a reusable glove with a minimum breakthrough time of 30 minutes. The
breakthrough time of the glove should be longer than the total duration of
product use. If work lasts longer than the breakthrough time, gloves should be