MSDS
Appropriate engineering
controls
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates
should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation,
or other engineering controls to maintain airborne levels below recommended exposure limits. If
exposure limits have not been established, maintain airborne levels to an acceptable level.
Individual protection measures, such as personal protective equipment
Eye/face protection
Wear safety glasses with side shields (or goggles).
Skin protection
Hand protection
Wear protective gloves.
Other
Wear appropriate chemical resistant clothing.
Respiratory protection
Wear positive pressure self-contained breathing apparatus (SCBA). Air monitoring is needed to
determine actual employee exposure levels.
Thermal hazards
Wear appropriate thermal protective clothing, when necessary.
General hygiene
considerations
Always observe good personal hygiene measures, such as washing after handling the material
and before eating, drinking, and/or smoking. Routinely wash work clothing and protective
equipment to remove contaminants.
9. Physical and chemical properties
Appearance
Physical state
Liquid.
Form
Aerosol.
Color
Clear. Colorless.
Odor
Ethereal and sweetish odor.
Odor threshold
Not available.
pH
Not available.
Melting point/freezing point
-112 °F (-80 °C) estimated
Initial boiling point and boiling
range
131 °F (55 °C) estimated
Flash point
None.
Flame extension
None.
Evaporation rate
> 1 Very fast (BuAc = 1)
Flammability (solid, gas)
Not available.
Upper/lower flammability or explosive limits
Flammability limit - lower
(%)
Not applicable.
Flammability limit - upper
(%)
Not applicable.
Vapor pressure
313.4 kPa
Vapor density
> 1 (air = 1)
Relative density
1.55
Solubility (water)
< 140 ppm
Partition coefficient
(n-octanol/water)
Not available.
Auto-ignition temperature
Not available.
Decomposition temperature
Not available.
Viscosity (kinematic)
Not available.
Percent volatile
100 % estimated
10. Stability and reactivity
Reactivity
The product is stable and non-reactive under normal conditions of use, storage and transport.
Chemical stability
Material is stable under normal conditions.
Possibility of hazardous
reactions
No dangerous reaction known under conditions of normal use.
Conditions to avoid
When exposed to extreme heat or hot surfaces, vapors may decompose to harmful or fatal
corrosive gases such as hydrogen fluoride.
Incompatible materials
Strong oxidizing agents.
Hazardous decomposition
products
Hydrogen fluoride.
3 / 7
Material name: Contact Cleaner
2428 Version #: 01 Issue date: 08-28-2013
SDS US