SDS
US. NIOSH: Pocket Guide to Chemical Hazards
ValueComponents
Form
Type
TWA 100 mg/m3Distillates (petroleum),
hydrotreated light (CAS
64742-47-8)
STEL 10 mg/m3 Mist.Paraffin oils (petroleum),
catalytic dewaxed heavy
(CAS 64742-70-7)
TWA 5 mg/m3 Mist.
STEL 10 mg/m3 Mist.Paraffin oils (petroleum),
catalytic dewaxed light
(CAS 64742-71-8)
TWA 5 mg/m3 Mist.
STEL 10 mg/m3 Mist.Petrolatum (CAS
8009-03-8)
TWA 5 mg/m3 Mist.
US. AIHA Workplace Environmental Exposure Level (WEEL) Guides
ValueComponents Type
TWA 165.5 mg/m3d-Limonene (CAS
5989-27-5)
30 ppm
No biological exposure limits noted for the ingredient(s).
Biological limit values
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates
should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation,
or other engineering controls to maintain airborne levels below recommended exposure limits. If
exposure limits have not been established, maintain airborne levels to an acceptable level.
Appropriate engineering
controls
Individual protection measures, such as personal protective equipment
Wear safety glasses with side shields (or goggles).
Eye/face protection
Skin protection
Wear protective gloves such as: Nitrile. Neoprene.
Hand protection
Wear appropriate chemical resistant clothing. Use of an impervious apron is recommended.
Other
If engineering controls are not feasible or if exposure exceeds the applicable exposure limits, use a
NIOSH-approved cartridge respirator with an organic vapor cartridge. Use a self-contained
breathing apparatus in confined spaces and for emergencies. Air monitoring is needed to
determine actual employee exposure levels.
Respiratory protection
Wear appropriate thermal protective clothing, when necessary.
Thermal hazards
When using do not smoke. Always observe good personal hygiene measures, such as washing
after handling the material and before eating, drinking, and/or smoking. Routinely wash work
clothing and protective equipment to remove contaminants. Contaminated work clothing should not
be allowed out of the workplace.
General hygiene
considerations
9. Physical and chemical properties
Appearance
Liquid.
Physical state
Liquid.
Form
Blue green
Color
Pleasant.
Odor
Odor threshold
Not available.
pH
Not available.
Melting point/freezing point
-56.2 °F (-49 °C) estimated
Initial boiling point and boiling
range
380 °F (193.3 °C) estimated
Flash point
192 °F (88.9 °C) Tag Closed Cup
Evaporation rate
Slow.
Not available.
Flammability (solid, gas)
4 / 9
Material name: 3-36® Multi-Purpose Lubricant & Corrosion Inhibitor
03006 Version #: 03 Revision date: 04-14-2016 Issue date: 10-31-2013
SDS US