7. Handling and storage
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Pressurized container: Do
not pierce or burn, even after use. Do not use if spray button is missing or defective. Do not spray
on a naked flame or any other incandescent material. Do not smoke while using or until sprayed
surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame,
sparks, or other sources of ignition. Use caution around energized equipment. The metal container
will conduct electricity if it contacts a live source. This may result in injury to the user from electrical
shock and/or flash fire. Avoid prolonged or repeated contact with skin. Avoid prolonged exposure.
Use only in well-ventilated areas. Wear appropriate personal protective equipment. Wash hands
thoroughly after handling. Avoid release to the environment. Observe good industrial hygiene
practices. For product usage instructions, please see the product label.
Precautions for safe handling
Level 3 Aerosol.
Pressurized container. Protect from sunlight and do not expose to temperatures exceeding
50°C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near an open flame,
heat or other sources of ignition. This material can accumulate static charge which may cause
spark and become an ignition source. Store in a well-ventilated place. Store away from
incompatible materials (see Section 10 of the SDS).
Conditions for safe storage,
including any incompatibilities
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
ValueComponents
Form
Type
PEL 9000 mg/m3carbon dioxide (CAS
124-38-9)
5000 ppm
PEL 5 mg/m3 Mist.Light mineral oil (CAS
8042-47-5)
PEL 5 mg/m3 Mist.Petrolatum (CAS
8009-03-8)
US. ACGIH Threshold Limit Values
ValueComponents
Form
Type
STEL 30000 ppmcarbon dioxide (CAS
124-38-9)
TWA 5000 ppm
TWA 5 mg/m3 Inhalable fraction.Light mineral oil (CAS
8042-47-5)
TWA 10 mg/m3n-Butyl stearate (CAS
123-95-5)
TWA 5 mg/m3 Inhalable fraction.Petrolatum (CAS
8009-03-8)
US. NIOSH: Pocket Guide to Chemical Hazards
ValueComponents
Form
Type
STEL 54000 mg/m3carbon dioxide (CAS
124-38-9)
30000 ppm
TWA 9000 mg/m3
5000 ppm
TWA 100 mg/m3Distillates (petroleum),
hydrotreated light (CAS
64742-47-8)
STEL 10 mg/m3 Mist.Light mineral oil (CAS
8042-47-5)
TWA 5 mg/m3 Mist.
STEL 10 mg/m3 Mist.Petrolatum (CAS
8009-03-8)
TWA 5 mg/m3 Mist.
No biological exposure limits noted for the ingredient(s).
Biological limit values
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates
should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation,
or other engineering controls to maintain airborne levels below recommended exposure limits. If
exposure limits have not been established, maintain airborne levels to an acceptable level.
Appropriate engineering
controls
3 / 9
Material name: 2-26® Multi-Purpose Precision Lubricant
02004 Version #: 04 Revision date: 04-11-2016 Issue date: 05-12-2014