SDS
7. Handling and storage
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Pressurized container: Do not pierce or burn, even after use. Do not use if spray
button is missing or defective. Do not spray on a naked flame or any other incandescent material.
Do not smoke while using or until sprayed surface is thoroughly dry. Use with adequate ventilation.
Open doors and windows or use other means to ensure a fresh air supply during use and while
product is drying. If you experience any symptoms listed on this label, increase ventilation or leave
the area. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other
sources of ignition. Use caution around energized equipment. The metal container will conduct
electricity if it contacts a live source. This may result in injury to the user from electrical shock
and/or flash fire. Avoid breathing mist or vapor. Avoid breathing gas. Avoid contact with eyes, skin,
and clothing. Avoid prolonged exposure. Use only in well-ventilated areas. Should be handled in
closed systems, if possible. Wear appropriate personal protective equipment. Observe good
industrial hygiene practices. Avoid release to the environment. Do not empty into drains. For
product usage instructions, please see the product label.
Precautions for safe handling
Level 1 Aerosol.
Contents under pressure. Do not puncture or incinerate container. Do not expose to heat or store
at temperatures above 49 °C/120 °F. Do not handle or store near an open flame, heat or other
sources of ignition. Exposure to high temperature may cause can to burst. Store in a
well-ventilated place. Store away from incompatible materials (see Section 10 of the SDS).
Conditions for safe storage,
including any incompatibilities
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
ValueComponents Type
PEL 9000 mg/m3Carbon dioxide (CAS
124-38-9)
5000 ppm
US. OSHA Table Z-2 (29 CFR 1910.1000)
ValueComponents Type
Ceiling 200 ppmTetrachloroethylene (CAS
127-18-4)
TWA 100 ppm
US. ACGIH Threshold Limit Values
ValueComponents Type
STEL 30000 ppmCarbon dioxide (CAS
124-38-9)
TWA 5000 ppm
STEL 100 ppmTetrachloroethylene (CAS
127-18-4)
TWA 25 ppm
US. NIOSH: Pocket Guide to Chemical Hazards
ValueComponents Type
STEL 54000 mg/m3Carbon dioxide (CAS
124-38-9)
30000 ppm
TWA 9000 mg/m3
5000 ppm
Biological limit values
ACGIH Biological Exposure Indices
ValueComponents Determinant Specimen Sampling Time
0.5 mg/l Tetrachloroethy
lene
Blood
*
Tetrachloroethylene (CAS
127-18-4)
3 ppm Tetrachloroethy
lene
End-exhaled
air
*
* - For sampling details, please see the source document.
3 / 9
Material name: Brakleen® Brake Parts Cleaner
05089, 05089T, 85089, 85089AZ Version #: 03 Revision date: 10-29-2015 Issue date: 12-20-2013
SDS US