Specifications
Installation 9
+
-
FUSE 250 AMP
PN 36436
(STELLAR SUPPLIED)
UNDERHOOD
TRUCK BATTERY
MASTER
250 AMP
Holder: PN 32523
AUX BATTERY
-
+
CRANE
COMPARTMENT
CAB OR CRANE
10 AMP
POWER
SWITCH
START MOTOR
SOLENOID
GROUND POST
CRANE HARNESS
GROUND
GROUND
LOCATE AUX BATTERY AS
CLOSE TO CRANE AS POSSIBLE
GROUND
POWER
OPT1
OPT2
SWITCH
(NOT SUPPLIED)
POWER SOURCE FOR
RADIO REMOTE
Torque Spec
Large Nuts: 35 in-lbs
Small Nuts: 15 in-lbs
Minimum Wire Sizes:
EC3200 - #2
EC4000 - #2
EC5000 - #2
EC6000 - 1/0
Operating the crane without
the truck engine running could allow the truck
battery to be discharged below levels required
for starter cranking power.
FUSE 250 AMP
PN 36436
(STELLAR SUPPLIED)
Holder: PN 32523
SAFETY BRAKE
87A
30
86
85
87
NOTICE
EC3200 Wiring Diagram (Two Battery)