Operator`s manual

30
Operators Manual
Problem Solving
In the unlikely event of the machine developing a problem, details are given in the table
below (figure 3) on how to deal with common faults that can be easily remedied by
the operator.
Safety First! Should the remedy given below not cure the problem, or the
fault is not listed, DO NOT ATTEMPT TO CURE THE FAULT YOURSELF.
Contact your machine supplier for assistance.
Figure 3
Fault Possible Cause Remedy
Waste tray overflowing Level sensor incorrectly Ensure sensor is placed
located or jamming correctly in the tray
Incorrect drinks Ingredient canisters Refit canisters into their
dispensed located incorrectly correct positions
Leaking from dispense Mixing bowls/chambers Refit correctly and ensure
area fitted incorrectly that all mixing stations
are water tight
Low water showing Water supply Ensure water supply is
on LCD display turned off turned on at stop-tap
Blank LCD display Electricity supply Ensure electricity supply
turned off is turned on at the mains
Cups jamming Incorrect cup size Remove cups from cup
turret and replace with
correct size cups
No change given (i) Coin tubes jamming Clear coin tubes and
from change-giver check for blockage
(where fitted)
(ii) Coin tubes empty or Check and refill coin tubes
below pre-set level where necessary
Coffee brewer unit (i) Incorrect paper fitted Remove and fit correct
jamming 90mm filter paper
(ii) Filter paper loaded Reload paper and ensure
incorrectly that it feeds correctly
(iii)Paper fouling on Adjust brewer guard.
brewer guard DO NOT REMOVE