Operator`s manual

9. Remove the drip tray from the machine. Empty and
clean.
Clean around the cup station area with a damp
sanitised cloth.
Wipe down the interior of the door. Clean the base,
sides and back of the machine.
Replace the drip tray.
10. Undo the thumb screws and remove cup throat
complete with drain pipe (a).
Clean cup throat and pipe in the sanitiser solution.
Rinse components with clean water and dry
thoroughly.
Reassemble to machine ensuring that drain pipe is
correctly located through drain hole.
11. Check the levels of the cups in the cup stack.Where
necessary, remove the cup stack lid and fill.
Important: Do not fill the tube directly above the
cup dispense position.Allow the cup turret to rotate
a full tube to the cup dispense position.Rotating the
cup turret by hand will damage the mechanism.
DO NOT TOUCH THE CUPS WITH YOUR
HANDS.Allow the cups to drop into the cup stack
directly from the packaging. Replace lid.
12. Un-lock the cashbox (where fitted); remove and
empty.
Refit the cashbox to the machine, turning the lock
to secure.
15