Programming Procedures Refreshment Center Operators’ Guide
4800006 70 December 2004
VIEW MACHINE TEMPERATURE
1. Press . The display shows
0
. This example shows that the machine
temperature is 38
0
degrees Fahrenheit.
NOTE
The temperature reading may display one of the following instead of “TEMP”,
depending on conditions in the machine:
- XX is the number of minutes left in the health control grace period
(see "Health Control" on page 42)
- a health control error has occurred.
- the machine is currently in a passive defrost cycle
- the temperature has been over the health control limit for x.x minutes.
2. If “ ” replaces “F” or “C” after the temperature, then the temperature is invalid. The last
valid temperature is shown. Check diagnostics for the cause, usually a faulty sensor.
3. A decimal point following “F” or “C” indicates the software has turned the compressor
on. If the compressor is not on, check the related wiring.
4. A comma after the “F” or “C” indicates the software is currently performing a defrost.
5. To change the display units, press . The display now shows .
6. CONTINUE.
VIEW SUREVEND SOFTWARE VERSION
1. Press , and press until the display shows .”XXX” represents
the current SureVend software version number.
2. CONTINUE.
VIEW SOFTWARE VERSION
1. Press , and press until the display shows . "XXX.XX" represents
the current software version number.
2. CONTINUE.