GALLON/ 3.78 LITER ULTRASONIC HUMIDIFIER MODEL# EE-5301, ,EE-5301(G), ,EE-5301(P) PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE.
TABLE OF CONTENTS Table of Contents P.1 Important Safety Instructions P. 2 General Safety Instructions P.3 List of Main Parts P.4 Tech. Specifications, Contents of Packaging P.5 Operation and Use P.5-7 Maintenance P.8-9 Trouble Shooting P.10 Service Center Information P.10 Warranty Information P.12 Warranty Card P.
IMPORTANT SAFETY INSTRUCTIONS INTRODUCTION Thank you for purchasing our CRANE Ultrasonic Humidifier. Each unit has been manufactured to ensure safety and reliability. Before using the humidifier for the first time, please read the instructions carefully, and keep them for further reference. WARNING! READ AND SAVE THESE INSTRUCTIONS. Failure to follow all the instructions listed below may result in electric shock, fire and/or serious personal injury. 1.
GENERAL SAFETY INSTRUCTIONS WARNING! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire or serious personal injury. The warnings, cautions, and instruction discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are a factor which cannot be built into this product, but must be supplied by the operator.
LIST OF MAIN PARTS PARTS DESCRIPTION Fig. 1 (Central Body) 1. On/Off Switch/Regulator Control Knob 2. Central body with water basin 3. Indicator light Fig. 1 Fig. 2 (Top of Water Tank) 4. Vapor Outlet Channel 5. Water Tank Handle Fig. 2 Fig. 3 (Water Basin) 6. Nebulizer 7. Vaporization Chamber 8. Fan Vent 9. Valve Opener 10. Water Level Sensor Fig. 3 Fig. 4 (Bottom of Water Tank) 11.Water Tank Valve 12. Water Tank Cap 13. Vapor Outlet channel Fig. 4 Fig. 5 (Water Tank Lid) 14. Water Tank Lid 15.
TECHNICAL SPECIFICATIONS: Rating Voltage Frequency Power Water Tank Capacity Output Per 24 Hours Run Time Per Tank Humidifying Capacity Noise 120V 60Hz 38W Approx. 0.9 Gallon / 3.3 Liter Approx. 2.3 Gallon / 8.7 Liter Min. 10 Hours Up to 250 sq.ft. / 23 m2 < 35 (dB) A CONTENTS OF PACKAGING a. b. c. d. Instruction Manual Central Humidifier Body Water Tank Water Tank Lid with Vapor Output Slot If any of the above items are missing, please contact our service department at 1-888599-0992 (http://www.
ASSEMBLY 1. Lift the water tank off the central body. 2. Turn over the water tank and unscrew the water tank cap at the bottom of the tank by turning it counterclockwise. (See Fig. 6) Fig. 6 3. Fill water tank with cold water; do not fill all the way to the rim. DO NOT CARRY FULL WATER TANK BY HANDLE. ALWAYS HOLD FULL WATER TANK WITH TWO HANDS ON EITHER SIDE OF WATER TANK (See Fig. 7). Note: To avoid possible white dust due to hard water it is recommended to use distilled water. DO NOT use hot water.
7. The Indictor Light will turn on. In a few seconds mist will start emitting through the openings at output slot. 8. Use the control knob to adjust the intensity of the vapor output. Turning the knob clockwise will increase the moisture output, turning the knob counterclockwise will reduce the moisture output (see Fig. 10). Fig. 10 9. When the humidifier runs out of water the humidifier will automatically shut off and the mist will stop.
MAINTENANCE CAUTION: Always be sure that the appliance is unplugged and switched OFF before cleaning or attempting to store the item. NEVER PLUG OR UNPLUG UNIT WITH WET HANDS. DO NOT leave water in water tank or water basin when unit is not in use as it may result in the build up of mineral deposits and bacteria that can inhibit the output efficiency of the humidifier. PLEASE NOTE that if water remains in the water tank for more than a day or two, bacterial growth is possible.
5. When cleaning the water basin do not place the nebulizer directly under the water tap. 6. Never immerse the unit in water or let water enter the fan vent or any other openings. 7. It is normal for water to be in the water basin. However water must not get inside the central body. If this should happen, take the humidifier to an authorized service center before using it again. 8. Clean the inside of the water tank at least once a week, as follows: A.
TROUBLE SHOOTING CAUTION: DO NOT attempt to repair the motor or nebulizer yourself. If the humidifier continues to not operate please call our service center (see toll free number below). Problem Humidifier is working than stops: If humidifier does not work at all: If there is a strange odor: The power light is on but there is no mist being emitted: White dust appears and settles outside the humidifier: Solution Ensure that water level float is assembled properly.
LIMITED WARRANTY Thank you for purchasing a top quality Crane product. This Ultrasonic Humidifier was tested and meets our stringent quality standards. This product is warranted to be free from manufacturing defects under normal use and conditions for 1 year. WARRANTY IS ONLY VALID WITH A DATED PROOF OF PURCHASE.
WARRANTY CARD In case you find this product to be defective please proceed as follows: A. Within 90 days of purchase: return the product to your retailer for a replacement or a refund. B. After 90 days and within the warranty period: send the product and all of its accessories to our service center. The consumer will be responsible for all shipping costs to the Crane Service Center. Crane will not assume responsibility for loss or damages to the product being returned to us.