User Manual

Auto Power
If Camden EC2 is situated in a rack full of other outboard equipment and preamps, it can be
configured to automatically power on/off when power is switched on from a central location
from inside the rack or a power conditioner when power is detected in its power supply.
To enable Auto Power, you will need to remove Camden EC2’s top panel and move a specific
jumper:
1. Ensure Camden EC2 is powered off and the power connector has been removed. Wait
30 seconds before continuing.
2. Place Camden EC2 on a flat surface and carefully remove the screws fixing the top
panel.
3. Before reaching inside Camden EC2, firmly touch it’s metal chassis to discharge any
built-up static electricity.
4. Locate the ‘Auto Power’ label.
5. Carefully remove the black jumper from the off position and reposition it over both legs
on the to bridge the connection and enable Auto Power On/Off.
6. Re-fix the top panel back onto Camden EC2’s top panel.
Camden EC2 Quick Start Guide -Page 7- ©2020 Cranborne Audio Ltd