Operation Manual
9 
ATTENTION: Installation of baking oven with chimney horizontal is allowed only with the 
waste gas line box, partnumber 43661 (new version ) and without chimney-adapter. 
ATTENTION: For the reason of saving of weight the oven for an OEM (producer of 
caravans or motorhomes) might be also delivered without the outer housing. 
The waste gas line through chimney pipe has to be in upward position. Maximum length of the 
waste gas line is 2.000 mm. The maximum elevation difference between the upper edge of oven 
and the point of waste gas outlet from the chimney is 1.500 mm. 
Walls and components closer than 50 mm to the waste gas exhaust have to be wrapped or 
protected with materials belonging to M0 fire-resistant group. 
Ø 50 mm flexible pipe of the waste gas exhaust made of a high-grade steel has always to be 
fixed at the outlet from the oven and at the inlet to the chimney adapter by means of one strap 
with a screw thread Ø 50 - Ø 60 mm (Truma´s thread appertaining to the pipe). 
7.1 THE APPLIANCE HAS TO BE INSTALLED IN A SAFE DISTANCE FROM 
INFLAMMABLE MATERIALS. 
7.2 PROTECTION AGAINST OVERHEATING 
All walls or components which are closer to the appliance than the minimum distance in the 
drawing (see Figures 3 - 6) have to be wrapped or protected with materials belonging to M0 
fire-resistant group. 
7.3 REMOVAL OF THE APPLIANCE FROM FURNITURE 
a)  Close the main gas tap 
b) Release fastening screws 
c)  Disconnect gas adapter and/or electrical cables. 
8. USE THE APPLIANCE ONLY IN A SUFFICIENTLY VENTED ROOM 
If the appliance is being used, venting openings shall to be without obstructions. 