Operation Manual
5 
ATTENTION! 
When replacing a gas cylinder the following safety measures have to be carried out: 
a)  Close the taps on the appliance (turn the knob into position 0); 
b)  Make sure that no flame or flaming articles are located close to it; 
c)  Close the tap of the cylinder being replaced; 
d)  Unscrew the pressure reducer from the empty cylinder, take the last one out of the 
case and replace it with a new gas cylinder – when connecting a new gas cylinder 
proceed in the reverse sequence. 
Test theleakage by applying of soapy water in the above mentioned way. 
e)  Fire up the burner and check the proper run; otherwise refer to a specialised 
technician. 
3.1 CASE FOR GAS CYLINDERS 
The case for gas cylinders has to be spacious enough for the intended type of cylinder with 
installed pressure regulator. 
4. VISUAL CONTROL OF FLAME 
a)  The flame has to burn still. It has to be predominantly blue coloured and with clear 
contours. 
b)  If the flame does not burn steady, it is necessary to check whether air inlet openings 
(Venturi tube) are free of obstacles. Otherwise the obstacles have to be removed. 
5. POWER SUPPLY AND ELECTRICAL CONNECTION: 
The electronic ignition of the grill and oven burners requires a 12 V DC power supply. 
ELECTRICAL CONNECTION 
To connect the appliance a twin core, 1,5 mm
2
 red and black cable shall be used and 
connected to the terminal board on the back of the appliance. This terminal board has both 
poles marked with + and -. The + pole is to be identified with the red colour cable. When 
connecting the cables it is absolutely necessary to observe the right polarity! The electric 
circuit has to be protected against fusion with a 3 A fuse (not supplied with the appliance). 