Operation Manual
4 
These openings have to be from time to time checked and/or cleaned by the user (e.g. clean 
the waste-gas output from snow and the combustion air inlet from melting snow in winter). 
The opening of the waste gas outlet must not be placed at the entry door and under 
ventilation openings.
If waste gas is discharged through the roof it is necessary to check whether the waste gas line 
is installed in the upward position. 
2. CONNECTING THE APPLIANCE TO THE GAS SUPPLY 
Connecting the appliance to the gas supply can be only executed using gas-tight connector or 
standardised tubing connection (max. length 1.5 metres), which have to be replaced before 
their expiration date. 
When laying rubber tubings it is necessary to make sure that they do not touch metal parts, 
which become extremely hot during the use of appliance, e.g. ones under the burners. 
When using pipes to connect the appliance they have to be made of galvanised iron or 
copper. These pipes have to be used with a gas-tight connector. After completion of the gas 
connections the gas lines has to be tested for gas leakage by applying soapy water over 
connection points and gas lines; gas leaks will show up as bubbles where the gas leak occurs. 
ATTENTION: DURING INSTALLATION AND CONNECTION OF APPLIANCE 
THE GAS PIPE CANNOT BE TURNED, PULLED OR IN A DIFFERENT WAY 
STRAINED. 
3. GAS CYLINDERS 
Gas cylinders usually used in the country where the appliance was sold have to be used. The 
usable gastype is clearly definied on the package and on the wipe resistant label on the 
backside of the appliance. 
USE OF PRESSURE OR GAS DIFFERENT FROM INSTRUCTIONS CAN CAUSE 
AN UNSTABLE RUNNING CONDITIONS OF THE APPLIANCE; THEREFORE 
THE PRODUCER REFUSES ANY RESPONSIBILITY CONCERNING THE 
CONNECTION WITH UNQUALIFIED HANDLING OF THE APPLIANCE. 
In any case the following instruction have to be followed: 
Gas cylinders with tap and pressure reducer have to be positioned in vertical position in 
a case intended for this purpose. Input of cylinders must not be obstructed. 
Replacement of the gas cylinder has to be fluent and without any difficulties. 
AFTER USE THE GAS CYLINDER HAS TO BE ENCLOSED 